Related function codes<br />
Function<br />
code<br />
Name<br />
V/f control<br />
Vector<br />
control<br />
F40 Torque Limiter 1-1 Y Y<br />
F41 Torque Limiter 1-2 Y Y<br />
E16 Torque Limiter 2-1 Y Y<br />
E17 Torque Limiter 2-2 Y Y<br />
H73<br />
Torque Limiter (Operating<br />
conditions)<br />
Y<br />
Y<br />
H74 Torque Limiter (Control target) N Y<br />
H75 Torque Limiter (Target quadrants) N Y<br />
H76<br />
Torque Limiter<br />
(Frequency increment limit for<br />
Y<br />
N<br />
braking)<br />
E61 to E63<br />
Terminal [12] Extended Function<br />
Terminal [C1] Extended Function<br />
Terminal [V2] Extended Function<br />
Y<br />
Y<br />
Remarks<br />
7: Analog torque limit value A<br />
8: Analog torque limit value B<br />
• Torque limit control mode<br />
Torque limit is performed by limiting torque current flowing across<br />
the motor.<br />
The graph below shows the relationship between the torque and the<br />
output frequency at the constant torque current limit.<br />
• Torque limiters 1-1, 1-2, 2-1 and 2-2 (F40, F41, E16 and E17)<br />
Data setting range: -300 to 300 (%), 999 (Disable)<br />
These function codes specify the operation level at which the torque<br />
limiters become activated, as the percentage of the motor rated torque.<br />
Function code Name Torque limit feature<br />
F40 Torque limiter 1-1 Driving torque current limiter 1<br />
F41 Torque limiter 1-2 Braking torque current limiter 1<br />
E16 Torque limiter 2-1 Driving torque current limiter 2<br />
E17 Torque limiter 2-2 Braking torque current limiter 2<br />
Although the data setting range for F40, F41, E16, and E17 is from positive to negative values (–300% to<br />
+300%), specify positive values in practice. Specifying a negative value causes the inverter to interpret it<br />
as an absolute value.<br />
The torque limiter determined depending on the overload current actually limits the torque current output.<br />
Therefore, the torque current output is automatically limited at a value lower than 300%, the maximum<br />
setting value.<br />
• Analog torque limit values (E61 to E63)<br />
The torque limit values can be specified by analog inputs through terminals [12], [C1], and [V2] (voltage or current).<br />
Set E61, E62, and E63 (Terminal [12] Extended Function, Terminal [C1] Extended Function, and Terminal [V2]<br />
Extended Function) as listed below.<br />
Data for E61, E62, or E63 Function Description<br />
7 Analog torque limit value A Use the analog input as the torque limit value<br />
specified by function code data (= 7 or 8).<br />
8 Analog torque limit value B Input specifications: 200% / 10 V or 20 mA<br />
If the same setting is made for different terminals, the priority order is E61>E62>E63.<br />