Examples:<br />

• Normal (linear) V/f pattern<br />

• V/f pattern with three non-linear points<br />

• Base Frequency 1 (F04)<br />

Data setting range: 25.0 to 500.0 (Hz)<br />

Set the rated frequency printed on the nameplate labeled on the motor.<br />

• Rated Voltage at Base Frequency 1 (F05)<br />

Data setting range:<br />

0: Output a voltage in proportion to input voltage (The Automatic Voltage Regulator (AVR) is disabled.)<br />

80 to 240 (V): Output an AVR-controlled voltage for 230 V series<br />

160 to 500 (V): Output an AVR-controlled voltage for 460 V series<br />

Set "0" or the rated voltage printed on the nameplate labeled on the motor.<br />

- If F05 = 0, the rated voltage at base frequency is determined by the AC Line Voltage of the inverter. The output<br />

voltage will vary as the input voltage fluctuates.<br />

- If F05 = an arbitrary value other than 0, the inverter automatically keeps the output voltage constant in line with<br />

the setting. When any of the auto torque boost, auto energy saving, etc. is enabled, the F05 data should be<br />

equal to the rated voltage of the motor.<br />

4-36