• Torque limiter (Operating conditions) (H73)<br />

H73 specifies whether the torque limiter is enabled or disabled during acceleration/deceleration and running at<br />

constant speed.<br />

Data for H73 During accelerating/decelerating During running at constant speed<br />

0 Enable Enable<br />

1 Disable Enable<br />

2 Enable Disable<br />

The torque limiter and current limiter are very similar in function. If both are activated concurrently, they<br />

may conflict with each other and cause hunting (undesirable oscillation of the system). Avoid concurrent<br />

activation of these limiters.<br />

4-64