Configuration <strong>Tsunami</strong> <strong>MP.11</strong> <strong>5012</strong>-<strong>SUR</strong> <strong>Installation</strong> <strong>and</strong> <strong>Management</strong><br />
Interface Parameters<br />
SU B<strong>and</strong>width Limit Configuration via Radius Server<br />
SU B<strong>and</strong>width Limit Configuration via Radius Server is used for centralized management of SU’s Input <strong>and</strong> Output<br />
B<strong>and</strong>width throttling limits configuration.<br />
For example, consider the above diagram which has a Radius Server at its back-end with two different BSU’s: BSU1 <strong>and</strong><br />
BSU2 <strong>and</strong> one SU in roaming. During the registration of SU with BSU1, BSU1 sends SU information in the form of<br />
Access-Request frame to the Radius Server. The Radius Server validates SU’s MAC address <strong>and</strong> if the SU is authorized,<br />
it sends an Access-Accept frame with Vendor Specific Attributes to BSU1 which has B<strong>and</strong>width throttling limits<br />
configuration on it. Thus, BSU1 receives B<strong>and</strong>width throttling limits configuration for SU, with the SU’s Input b<strong>and</strong>width<br />
limit Vendor Specific Attribute Number as 1 <strong>and</strong> Output b<strong>and</strong>width limit Vendor Specific Attribute Number as 2.<br />
When SU moves from the range of BSU1 to BSU2, a similar process takes place <strong>and</strong> the Radius Server provides the<br />
same B<strong>and</strong>width limit values to the SU through BSU2. Thus the SU has same Input <strong>and</strong> Output B<strong>and</strong>width throttling limits<br />
Index throughout its roaming. This ensures a centralized management of SU’s Input <strong>and</strong> Output B<strong>and</strong>width throttling<br />
limits configuration via the Radius Server.<br />
When there is no B<strong>and</strong>width throttling limits configuration via Radius Server, BSU-SU follows the normal procedure of<br />
working.<br />
Ethernet<br />
To set the Ethernet speed, duplex mode, <strong>and</strong> input <strong>and</strong> output b<strong>and</strong>width limits, click Configure > Interfaces > Ethernet.<br />
You can set the desired speed <strong>and</strong> transmission mode by clicking on Configuration. Select from these settings for the<br />
type of Ethernet transmission:<br />
• Half-duplex means that only one side can transmit at a time.<br />
• Full-duplex lets both sides transmit.<br />
• Auto-duplex selects the best transmission mode available when both sides are set to auto-select.<br />
The recommended setting is auto-speed-auto-duplex.<br />
77