Configuration <strong>Tsunami</strong> <strong>MP.11</strong> <strong>5012</strong>-<strong>SUR</strong> <strong>Installation</strong> <strong>and</strong> <strong>Management</strong><br />
Syslog Parameters<br />
Syslog Parameters<br />
Overview<br />
System log messages are generated by the system by sending requests at various instances to the system log server.<br />
Every message in the system carries a priority of that message. This priority indicates the importance of the message.<br />
The messages which have a priority higher than the configured syslog priority are sent to Syslog Server.<br />
The Syslog tab is used to configure hosts or servers on the network that will receive syslog messages from the device.<br />
System message logging can be disabled if needed.<br />
1. Click Configure > Syslog to enable Syslog support for the device. The following parameters are configurable.<br />
• Enable Syslog: Select Enable Syslog checkbox to enable the Syslog functionality. To disable this functionality,<br />
clear this checkbox.<br />
• Syslog Lowest Priority Logged: The messages which have a priority lower (numerical value) than the<br />
configured Syslog priorities are sent to Syslog Server. The numerical values of the Syslog Priority messages are<br />
described below:<br />
Emergency: 0<br />
Alert:1<br />
Critical: 2<br />
Error: 3<br />
Warning: 4<br />
Notice: 5<br />
Info: 6<br />
Debug: 7<br />
Select the desired message priority from the Syslog Priority list.<br />
• Syslog Heartbeat Status: Heartbeat messages are dummy messages which are logged periodically to the syslog<br />
server. Select Enable to enable logging of Heartbeat messages by the syslog service.<br />
• Syslog HeartBeat Interval: Specifies the heartbeat message interval for which the heartbeat messages will be<br />
logged in seconds. By default, the Syslog HeartBeat Interval is 900 seconds.<br />