Resetting the CounterAfter replacing the 160K Maintenance Kit, perform the required control panel operations toreset their respective counters.When replacing the 160K Maintenance Kit, be sure to reset the counter on the control panel.1. On the control panel, press the < > and buttons at the same time.This displays the [Consumables Menu].Consumables MenuSerial Number2. Press the < > until [Reset Counter] isdisplayed.Consumables MenuReset Counter3. Press either the < > or button toselect so [Fuser Assembly] is displayed.Reset CounterFuser Assembly4. Press the < > so [Trans.BeltCleaner] isdisplayed.ResetCounterTrans.BeltCleaner5. Press either the < > or button toselect.Press OK to resetTrans.BeltCleaner6. Press the button.Resetting FuserTrans.BeltCleaner7. This resets the counter for the IBT beltcleaner.ResetcompletedforTrans.BeltCleaner8. Press the button to close themenu.7.1 Replacing Consumables 321