Chapter 4 - System Installation<br />
DANGER: AC power installation must be performed by a<br />
skilled and instructed person - see Section 2.12 on page 32.<br />
During installation, unauthorized third parties must be<br />
prevented, through the use of fail-safe lockout measures,<br />
from turning on power.<br />
Facility Overvoltage Protection<br />
The robot must be protected from excessive overvoltages and voltage spikes. If the<br />
country of installation requires a CE-certified installation or compliance with IEC 1131-2,<br />
the following information may be helpful. IEC 1131-2 requires that the installation must<br />
ensure that Category II overvoltages (i.e., line spikes not directly due to lightning strikes)<br />
are not exceeded. Transient overvoltages at the point of connection to the power source<br />
shall be controlled not to exceed overvoltage Category II, i.e., not higher than the impulse<br />
voltage corresponding to the rated voltage for the basic insulation. The user-supplied<br />
equipment or transient suppressor shall be capable of absorbing the energy in the<br />
transient.<br />
In the industrial environment, non-periodic overvoltage peaks may appear on mains<br />
power supply lines as a result of power interruptions to high-energy equipment (such as a<br />
blown fuse on one branch in a 3-phase system). This will cause high current pulses at<br />
relatively low voltage levels. Take the necessary steps to prevent damage to the robot<br />
system (for example, by interposing a transformer). See IEC 1131-4 for additional<br />
information.<br />
AC Power Diagrams<br />
1Ø<br />
200–240 VAC<br />
20 A<br />
L<br />
N<br />
E<br />
Note: F1 is user-supplied, must be slow-blow.<br />
F1 10 A<br />
L = Line<br />
N = Neutral<br />
E = Earth Ground<br />
E<br />
N<br />
L<br />
<strong>Adept</strong> <strong>Quattro</strong><br />
<strong>s650H</strong> <strong>Robot</strong><br />
1Ø 200–240 VAC<br />
User-Supplied<br />
AC Power Cable<br />
Figure 4-4. Typical AC Power Installation with Single-Phase Supply<br />
58 <strong>Adept</strong> <strong>Quattro</strong> <strong>s650H</strong> <strong>Robot</strong> User’s Guide, Rev A