<strong>3000</strong>sb2.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong> System Overview<br />

<strong>HiPath</strong> 3500<br />

2.7.3.2 UPSC-DR<br />

Introduction<br />

This board combines the power supply and battery management functions. No other components<br />

are required if operated as a power supply. To maintain short-term battery emergency<br />

operation after a power failure, that is, to use uninterruptible power supply functions, you must<br />

also connect a battery pack.<br />

An EPSU2-R external power supply must be used if the total number of U P0/E stations, analog<br />

stations, and stations connected using adapters is greater than 72.<br />

Additional power can be made available by connecting the external EPSU2-R power supply<br />

(see Section 2.7.6) To do this, connect the DC port on the EPSU2-R to the special –48 V DC<br />

input on the UPSC-DR. The UPSC-DR’s internal -48-V output is deactivated when the external<br />

power supply is connected.<br />

Technical specifications<br />

● Nominal voltage range: 100 VAC - 240 VAC<br />

● Nominal frequency: 50 Hz - 60 Hz<br />

● Ring generator: 75 VAC, 20/25/50 Hz<br />

● Partial voltages: +5 VDC, –48 V<br />

● Battery charger: 4 x 12 V (40,8 V-55,2 V)<br />

● Power consumption: approx. 180W<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />