<strong>3000</strong>sb4.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> in the LAN Network<br />

Applications over <strong>IP</strong><br />

4.8 Applications over <strong>IP</strong><br />

4.8.1 Call Detail Recording Central (CDRC) via <strong>IP</strong><br />

In <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong>, you can start up the central call data output function only once, which<br />

means that it is available to only one application at a time. Three different modes exist to support<br />

the various requirements of the different applications.<br />

Model-Specific Data<br />

Subject <strong>HiPath</strong> 3800 <strong>HiPath</strong> 3750<br />

<strong>HiPath</strong> 3700<br />

4.8.1.1 TFTP Client in <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong><br />

<strong>HiPath</strong> 3550<br />

<strong>HiPath</strong> 3500<br />

<strong>HiPath</strong> 3350<br />

<strong>HiPath</strong> 3300<br />

Feature available in x x x x<br />

Hardware requirements<br />

HG 1500 / LIMS HG 1500 / LIM<br />

Software requirements<br />

V5.0 or later V1.2 to V6.0 V1.2 or later V1.2 or later<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> External application<br />

TFTP client<br />

TFTP protocol<br />

TFTP<br />

server<br />

Alternative<br />

server<br />

Controlled by a programmable timer and a fixed threshold value determining the call data buffer<br />

capacity (around 80 percent of the call data buffer full), the TFTP client (<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong>)<br />

sends call data to the TFTP server (external application). If the system cannot set up a connection<br />

to the TFTP server, it addresses an alternative server. If this server is also unavailable,<br />

it outputs an SNMP trap or error message (“Unable to output data”). The system tries to set up<br />

another connection every 60 seconds. A call data buffer overflow causes an error message to<br />

be entered in the error history file.<br />