<strong>3000</strong>sb4.fm<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> in the LAN Network For internal use only<br />

Scenarios<br />

● Max. 64 nodes in the network without the <strong>5000</strong> RSM Feature Server<br />

● An optional HPCO V1.3 can be implemented (for max. 16 nodes in the network)<br />

– As an alternative, ProCenter Agile can be used at one node<br />

● An optional Xpressions Compact can be implemented centrally<br />

– As an alternative, Xpressions V3.0 can be implemented centrally<br />

4.10.3 Example 3<br />

<strong>IP</strong> Trunking <strong>HiPath</strong> <strong>3000</strong>/<strong>3000</strong>/<strong>5000</strong>, Gateway 2 and <strong>HiPath</strong> <strong>5000</strong> CS at Location 2 with<br />

Closed Numbering, Gateway 1 at Location 1 Establishes Open Numbering to Location 2<br />

Location 1<br />

Node 21<br />

Node 22<br />

Call no. 10<br />

Call no. 1000<br />

Call no. 1001<br />

<strong>IP</strong> workpoint on<br />

<strong>HiPath</strong> <strong>5000</strong> CS<br />

<strong>HiPath</strong> <strong>5000</strong><br />

including <strong>HiPath</strong> Com-<br />

Scendo Service<br />

Location 2:<br />

closed numbering<br />

Node 20<br />

● Functional scope between <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> CS corresponds to CorNet <strong>IP</strong><br />

● In this example, the private numbering plan should be used. Node numbers that are unique<br />

throughout the network should be configured for each location.<br />

● The workpoints of gateway 2 and <strong>HiPath</strong> <strong>5000</strong> CS establish a closed numbering plan at<br />

location 2.<br />

Dialing from gateway 2 to <strong>5000</strong> CS: node number + internal number.<br />

Dialing gateway 2 or <strong>5000</strong> CS from the PSTN: subscriber line (location 2) + internal number.<br />