<strong>3000</strong>sb6.fm<br />

For internal use only Middleware<br />

<strong>HiPath</strong> TAPI 120 V2.0<br />

6 Middleware<br />

6.1 <strong>HiPath</strong> TAPI 120 V2.0<br />

The 1st party CTI functionality is available for all <strong>HiPath</strong> <strong>3000</strong> models in conjunction with HG<br />

1500. Up to six TAPI 120 can be operated without a license. Licenses are mandatory for any<br />

additional TAPI 120s installed. The software, installation manual, and additional information<br />

(data sheet) can be found on the Internet at http://www.siemens.com/enterprise.<br />

6.1.1 <strong>HiPath</strong> TAPI 170 V2.0<br />

This TAPI driver supports Microsoft TAPI 2.1 (Windows NT 4.0) and TAPI 3.0 (Windows 2000/<br />

XP). The software is enabled by a license server. Test software, installation, manual and additional<br />

information (data sheet) can be found on the Internet at http://www.siemens.com/enterprise.<br />

Server Operating<br />

<strong>systems</strong><br />

Clients Operating <strong>systems</strong><br />

Connection<br />

variants<br />

Basic software<br />

package<br />

CSTA CSTA<br />

Interfaces<br />

Windows NT 4.0 (SP 6 or higher) or Windows 2000<br />

Windows†98, Windows NT 4.0 (SP 6 or higher), Windows 2000<br />

or Windows XP Professional<br />

V.24, S0 or LAN<br />

10 clients, 4 expansion packages up to 10, 25, 50 and 100 clients<br />

Depending on the model, up to four interfaces are available<br />

Applications Several applications can run in parallel, but they cannot send<br />

conflicting commands or be mutually exclusive<br />

Monitor points 1000<br />

Four monitor points are required, for example, to monitor a station<br />

with four applications over CSTA<br />

Call number Maximum of 6 digits<br />

length<br />

Load behavior incoming calls are rejected (busy) as soon as a traffic volume of<br />

1400 BHCA is exceeded. This happens when more than four<br />

calls are received within ten seconds. This does not affect call<br />

traffic within the node<br />