<strong>3000</strong>sb11.fm<br />

Identifying System Power Requirement For internal use only<br />

Check Whether the Output of a Power Supply Unit is Sufficient<br />

2. Determine secondary power requirement at the –48 V output<br />

power requirements of the boards/<br />

components used =<br />

+ power requirement of connected workpoint<br />

clients, key modules and adapters<br />

=<br />

= secondary power requirement at the<br />

48 V output =<br />

0.50 W 1 x CBCC<br />

2.80 W 1 x HXGS3 (including ventilator<br />

kit)<br />

0.00 W 1 x TS2<br />

0.00 W 3 x SLU8<br />

1.30 W 1 x 8SLA<br />

0.00 W 1 x SLC16N<br />

24.00 W 12 x BS3/1<br />

0.56 W 1 x optiset E memory<br />

4.32 W 6 x optiPoint 500 advance<br />

0.85 W 1 x optiset E advance conference/conference<br />

8.40 W 12 x optiPoint 500 basic<br />

2.40 W 8 x optiPoint 500 entry<br />

0.00 W 2 x Hicom Attendant BLF<br />

0.00 W 2 x optiPoint BLF<br />

0.40 W 8 x optiPoint key module<br />

0.50 W 2 x optiPoint acoustic adapter<br />

1.80 W 6 x analog telephones<br />

47.83 W<br />

The maximum nominal output of UPSC-D at the –48 V output amounts to 53 W and is<br />

enough to cover the specified power requirement.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />