<strong>3000</strong>sb2.fm<br />

<strong>HiPath</strong> <strong>3000</strong> System Overview For internal use only<br />

<strong>HiPath</strong> Cordless Office<br />

2.10 <strong>HiPath</strong> Cordless Office<br />

2.10.1 Introduction<br />

For Version 1.2 and later of <strong>HiPath</strong> <strong>3000</strong>, <strong>HiPath</strong> Cordless Office can be used on all <strong>systems</strong> of<br />

this product line.<br />

Direct connection<br />

The BS3/1 (S30807-H5482-X) and BS4 (S30807-U5491-X) base stations can be connected directly<br />

to the U P0/E interfaces on the central control boards in the <strong>HiPath</strong> 3550, <strong>HiPath</strong> 3350, Hi-<br />

Path 3500, and <strong>HiPath</strong> 3300. The connection must be made via one U P0/E interface each. A<br />

mix of base stations of types BS3/1 and BS4 is supported.<br />

To ensure the operation of a maximum of one base station on the central control board’s U P0/<br />

E interfaces of the <strong>HiPath</strong> 3550, <strong>HiPath</strong> 3350, <strong>HiPath</strong> 3500, and <strong>HiPath</strong> 3300, a BS3/S (X30807-<br />

X5482-X100) single-cell base station can be used. In this case, it is not possible to expand with<br />

additional base stations.<br />

However, base stations cannot be simultaneously connected to the SLC16/SLC16N board and<br />

the CBCC within one <strong>HiPath</strong> 3550 system.<br />

> The base stations BS3/1 (S30807-H5482-X), BS3/3 (S30807-H5485-X), and BS3/S<br />

Connecting cordless boards<br />

Base stations can be connected to the U P0/E interfaces of the following cordless boards:<br />

● SLC16N with <strong>HiPath</strong> 3550<br />

● SLCN in <strong>HiPath</strong> 3800<br />

> The SLC16 (S30810-Q2922-X) board is no longer supported in <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong><br />

(X30807-X5482-X100) are being phased out and can not longer be ordered. Use the<br />

successor product BS4 (S30807-U5491-X) instead of the types specified.<br />

You can continue to operate the base stations specified in conjunction with <strong>HiPath</strong><br />

<strong>3000</strong>. A mix of base stations of types BS3/1, BS3/3, and BS4 is also supported.<br />

V6.0 and later <strong>systems</strong>.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

2-80 <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description