<strong>3000</strong>sb5.fm<br />

For internal use only Serviceability<br />

Options in the Service Department<br />

5.3.11.2 Issuing and Saving Log Data<br />

Data is automatically logged in an area (LOG area) on the MCC reserved for this purpose. It<br />

cannot be switched off.<br />

If approximately 80 % of the MMC log area capacity is exceeded, a Class A error is issued.<br />

This error is dealt with like all Class A errors and is displayed on the optiPoint Attendant as “Revisor<br />

Alarm.”<br />

The log should now be read out and archived, in other words it should be saved in an archive file<br />

(file extension = arc). If an archive is not created, the oldest datablock is overwritten if there is<br />

a danger of overflow.<br />

You can only issue log entries using <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> Manager E. You cannot retrieve the log<br />

entries from the system until you have logged on as a user with “Revisor” rights.<br />

Archive<br />

If you request an archive (storage), the system checks whether or not there is already an archive<br />

file (file extension = arc). If it is a file with log data from a previous archive, the file must<br />

match the current customer. In case of a positive result, the system log entries are retrieved<br />

and attached to the existing data in the archive file. At the same time, the data in the system<br />

is deleted.<br />

If malfunctions occur during this procedure (for example, line interruption), the entire procedure<br />

ends and the archive has to be restarted.<br />

If no archive is requested, the revisor can retrieve, view, and print the log entries. However, log<br />

entries remain in the system.<br />

Multimedia Card (MMC)<br />

When replacing the multimedia card, the following applies:<br />

● If the memory area for logging data is empty, logging restarts.<br />

● If the memory area for logging data is not empty, logging continues.<br />