<strong>3000</strong>sb2.fm<br />

<strong>HiPath</strong> <strong>3000</strong> System Overview For internal use only<br />

<strong>HiPath</strong> 3550<br />

Table 2-16 EPSU2 - Technical Specifications<br />

Battery operation:<br />

● Permitted batteries<br />

Manufacturer/type number<br />

● Number of batteries<br />

● Size (Ah)<br />

● Nominal voltage<br />

● Overload protection<br />

EPSU2<br />

S30122-K7221-X1<br />

EPSU2<br />

S30122-K7221-X2<br />

● CSB/EVX-1270, Hitachi/HP6.5-12, Yuasa/NP6-12, Varta/<br />

Noack 43720303, Sonnenschein/0719143200, Panasonic/<br />

LCR12-7P<br />

● 4 units, 12 V each<br />

● 7Ah<br />

● 48 V (fully charged 54 V, discharge to 44 V)<br />

● Melting fuse 5 x 20 mm, 2.5 A/slow-blowing<br />

Nominal current 2.5A<br />

Overload protection Electronic current limiting circuit<br />

Ambient temperature In buildings, +5 to +45 °C (41 to 113 °F)<br />

Humidity 95%/non-condensing<br />

Cooling Natural convection<br />

Protection <strong>IP</strong> 21 (DIN 40050)<br />

Housing dimensions (W x D<br />

x H in mm)<br />

250 x 114 x 317<br />

Weight approx. 14.1 kg (incl. batteries) approx. 4.1 kg (without batteries)<br />

Symbol CE<br />

Personal safety, insulation EN60950 and IEC950<br />

Grounding, shielding Protection class 1, output is floating against ground.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

2-40 <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description