<strong>3000</strong>sb11.fm<br />

For internal use only Identifying System Power Requirement<br />

Check Whether the Output of a Power Supply Unit is Sufficient<br />

● <strong>HiPath</strong> 3500 with UPSC-DR<br />

The maximum nominal output of the –48 V output can be increased from 53 W to 140 W<br />

by using the EPSU2-R external power supply unit.<br />

● <strong>HiPath</strong> 3300 with USPSC-DR<br />

Due to build-up of heat, the 5 V output format can only be loaded with a maximum of 20 W.<br />

A maximum nominal output of 40 W is possible by using the EPSU2-R external power supply<br />

unit. In addition, the maximum nominal output of the –48 V output increases from 53 W<br />

to 140 W.<br />

Sample calculation for a <strong>HiPath</strong> 3550<br />

1. Determine secondary power requirement at the 5 V output<br />

power requirements of the boards/<br />

components used =<br />

= secondary power requirement at the<br />

5 V output =<br />

7.00 W 1 x CBCC<br />

10.00 W 1 x HXGS3 (including ventilator<br />

kit)<br />

0.90 W 1 x TS2<br />

2.40 W 3 x SLU8<br />

1.30 W 1 x 8SLA<br />

5.00 W 1 x SLC16N<br />

0.00 W 12 x BS3/1<br />

26.60 W<br />

The maximum nominal output of UPSC-D at the –5 V output amounts to 40 W and is<br />

enough to cover the specified power requirement.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />