<strong>3000</strong>sb5.fm<br />

For internal use only Serviceability<br />

Options in the Service Department<br />

5.3.8 Error Correction<br />

5.3.8.1 Automatic Error Correction<br />

One of the below recovery actions is assigned to each error in the error memory. These recovery<br />

actions are programmed to automatically correct errors that occur.<br />

● Hard restart<br />

● Reload board<br />

● Reload CDB backup<br />

● Port lockout<br />

● Power failure transfer (loop start)<br />

● None<br />

A watchdog activates continuous loops.<br />

If no recovery measure is assigned or if the one that is assigned fails, a service technician has<br />

to correct the error manually.<br />

5.3.8.2 Manual Error Correction Without <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> Manager E<br />

Manually Activating Restart (Reset)/Reload<br />

Pressing the reset button on the central control board<br />

● initiates a Reset (Hard restart of the entire system with the current CDB) if the button is<br />

pressed for less than 5 seconds. The Run LED lights up when the Reset button is pressed.<br />

● initiates a Reload if the button is pressed longer than 5 seconds. The Run LED disappears<br />

after approximately five seconds as verification that the reload has been initiated. The entire<br />

content of the customer database is replaced by its default version. All country and customer-specific<br />

settings are lost.<br />

Locking out and Releasing Boards and Ports<br />

You can lock out and release ports using the lockout switch located on the board. The lockout<br />

prevents renewed seizure after the current connection has finished. It creates<br />

● a port lockout in an outgoing direction on analog trunk boards.<br />

● a port lockout in outgoing and incoming directions on trunk boards.<br />

● a lockout of the entire board for subscriber line modules.<br />