<strong>3000</strong>sb2.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong> System Overview<br />

<strong>HiPath</strong> 3550<br />

2.3.6 Additional Power Supply from the EPSU2<br />

An EPSU2 external power supply must be used if the total number of U P0/E stations, analog<br />

stations, and stations connected using adapters is greater than 72.<br />

Additional power can be made available by connecting the external EPSU2 power supply. For<br />

this, the EPSU2’s DC connection needs to be connected to the special –48 VDC input on the<br />

UPSC-D. The UPSC-D’s internal -48-V output is deactivated when the external power supply<br />

is connected.<br />

EPSU2 Technical Specifications<br />

Table 2-16 EPSU2 - Technical Specifications<br />

EPSU2<br />

S30122-K7221-X1<br />

Scope of delivery ● EPSU2 AC/DC converter<br />

with four UPS batteries<br />

loaded<br />

● Operating instructions<br />

● AC connecting cable (protective<br />

grounding plug,<br />

IEC-320 socket)<br />

● DC cable to UPSC-D,<br />

length = 2 m<br />

AC power cable ● C39195-Z7001-C17 Euro angled<br />

● C39195-Z7001-C20 GBR angled<br />

EPSU2<br />

S30122-K7221-X2<br />

● EPSU2 AC/DC converter<br />

without batteries<br />

● Operating instructions<br />

● AC connecting cable (protective<br />

grounding plug,<br />

IEC-320 socket)<br />

● DC cable to UPSC-D,<br />

length = 2 m<br />

AC power 100 - 240 V AC<br />

Frequency range 47 to 63 Hz<br />

Connected output 200 W<br />

Output power consumption/<br />

nominal output<br />

140 W<br />

Mains/nominal voltage 54.2 V<br />

UPS batteries V39113-W5123-E891 V39113-W5123-E891<br />

Four batteries are supplied Batteries are not included in<br />

built-in.<br />

the scope of supply and must<br />

be ordered separately.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description 2-39