10.12.2012 Views

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>3000</strong>sb7.fm<br />

For internal use only Workpoints<br />

Attendant Consoles<br />

8.12.3 optiPoint Attendant<br />

Definition<br />

Switching services can be performed in <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> using a specially configured telephone.<br />

This optiPoint Attendant (AC) also serves as an intercept position at the same time. At<br />

the AC all calls accumulate if there is no direct inward dialing option, or if a station could not be<br />

contacted using the call allocation algorithm in Call Management (intercept). The operator then<br />

forwards the incoming calls to the relevant stations.<br />

The system telephones optiset E standard, optiset E advance plus/comfort, optiset E advance<br />

conference/conference, optiset E memory, optiPoint 500 basic, optiPoint 500 standard, and optiPoint<br />

500 advance as well as <strong>IP</strong> phones can be configured as an optiPoint Attendant.<br />

The function keys of the system telephone used for optiPoint Attendant are preset as follows<br />

and can be changed by the service technician if necessary:<br />

● Night answer (switches night answer on/off)<br />

● Telephone directory (opens the internal telephone directory)<br />

● Held calls (provides information on the number of held calls)<br />

● Busy override (goes into a busy connection)<br />

● Hold (puts a party on hold)<br />

● External 1 (first external call, incoming/outgoing)<br />

● External 2 (second external call, incoming/outgoing)<br />

● Disconnect (disconnect or connect a call)<br />

Depending on the individual customer’s requirements, optiPoint Attendant can be equipped<br />

with key modules and/or with busy lamp fields (optiPoint BLF). The number of function keys<br />

(particularly the internal name keys) is increased accordingly (Table 8-11).<br />

Total number of keys 16 32 48 64 90 106 122 180 196 212<br />

Number of key modules 1 2 3 4 – 1 2 – 1 2<br />

Keys on key modules 16 32 48 64 – 16 32 – 16 32<br />

Number of BLFs (optiPoint BLF) – – – – 1 1 1 2 2 2<br />

Keys on BLFs (optiPoint BLF) – – – – 90 90 90 180 180 180<br />

Table 8-11 optiPoint Attendant - Function key totals for additional key modules and BLFs<br />

When a total of 2 key modules and 2 optiPoint BLFs are connected up a maximum of 212 internal<br />

name keys (with internal station number) with busy lamp indicator can be shown.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description 8-117

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!