<strong>3000</strong>sb2.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong> System Overview<br />

<strong>HiPath</strong> 3500<br />

2.7.6 Additional Power Supply from the EPSU2-R<br />

An EPSU2-R external power supply must be used if the total number of U P0/E stations, analog<br />

stations, and stations connected using adapters is greater than 72.<br />

Additional power can be made available by connecting the external EPSU2-R power supply. To<br />

do this, connect the DC port on the EPSU2-R to the special –48 V DC input on the UPSC-DR.<br />

The UPSC-DR’s internal -48-V output is deactivated when the external power supply is connected.<br />

The additional EPSU2-R external power supply unit is installed in the ECR.<br />

EPSU2-R technical specifications<br />

Table 2-29 EPSU2-R - Technical Specifications<br />

EPSU2-R<br />

S30122-K7221-X900<br />

Scope of delivery ● EPSU2-R AC/DC converter without batteries<br />

● Operating instructions<br />

● Network connection cable from ECR to <strong>HiPath</strong><br />

3500 or <strong>HiPath</strong> 3300: C39195-Z7001-C14<br />

AC power 100 - 240 V Ac<br />

Frequency range 47 to 63 Hz<br />

Connected output 200W<br />

Output power consumption/nominal<br />

output<br />

140W<br />

Mains/nominal voltage 54.2 V<br />

UPS batteries V39113-W5123-E891<br />

Batteries are not included in the scope of supply and<br />

must be ordered separately.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description 2-63