10.12.2012 Views

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>3000</strong>sb2.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong> System Overview<br />

<strong>HiPath</strong> 3550<br />

2.3.4.2 Trunk Boards<br />

Table 2-13 Trunk Boards for <strong>HiPath</strong> 3550<br />

Board<br />

Name<br />

Ports per board<br />

Capacity Country<br />

B channels per board<br />

TCAS-2 2 60 1<br />

Max. number of<br />

boards per system<br />

ROW<br />

U.S.<br />

Type/Description<br />

1 x 2<br />

- Board for supporting country-specific<br />

CAS (Channel Associated Signaling) protocols<br />

x - Trunk board for analog lines<br />

x - Trunk board for analog lines<br />

x - Trunk board for analog lines including ALUM<br />

x - Trunk board for analog lines<br />

TLA 2 # 3<br />

TLA4 4 # 3<br />

TLANI4 4 # 3<br />

TLA8 8 # 3<br />

TS2 30 30 1 x - Board for primary rate access; can be used for tie trunk traffic.<br />

In <strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> V5.0 and later, the B channels in the<br />

TS2 board are subject to license. Consequently, the TS2<br />

boards (S30810-Q2913-X300) have been assigned a new<br />

hardware identification code. The new code prevents the<br />

board from being used in earlier versions. Functionality and<br />

layout of the board have not been changed.<br />

STLS2 2 4 # 3<br />

x - Board for ISDN basic rate access.<br />

STLS4 4 8 #<br />

Configuration of ISDN trunks, tie trunks, and stations (no<br />

feeding) on the same board is possible.<br />

3<br />

x x<br />

TST1 1 24 1 - x PRI board<br />

TMGL4 4 # 3<br />

- x Trunk board for analog lines<br />

TMQ4 4 8 # 3<br />

- x BRI board<br />

1 TCAS-2 provides two E1 CAS interfaces which, combined, can support up to 60 B channels. As <strong>HiPath</strong> 3550 supports a<br />

maximum of 30 B channels, a total of up to 30 B channels may be used.<br />

2 For selected countries only<br />

3 The maximum number is calculated on the basis of the system-specific capacity limits, See Section 2.1, "System-Related<br />

Capacity Limits".<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description 2-35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!