10.12.2012 Views

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

Administration HiPath 3000/5000 V7 IP systems

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>3000</strong>sb2.fm<br />

For internal use only <strong>HiPath</strong> <strong>3000</strong> System Overview<br />

Recommendations for CMA and CMS Utilization<br />

Table 2-36 Recommendations for CMA and CMS Utilization<br />

Trunk<br />

connection<br />

Reference<br />

clock<br />

<strong>HiPath</strong> Cordless<br />

Office<br />

Trunk<br />

connection<br />

Reference<br />

clock<br />

<strong>HiPath</strong> Cordless<br />

Office<br />

No Yes No Yes<br />

● Networking via Ethernet/<strong>IP</strong> (10BaseT) lines:<br />

System 1 System(s) n+1<br />

No trunk/ – CMS<br />

analog<br />

trunk<br />

3 CMS/CMA No trunk/ – CMS<br />

(see Table 2- analog<br />

37) trunk<br />

3 CMS/CMA<br />

(see Table 2-<br />

37)<br />

ISDN S0 (not alwaysac-<br />

Via<br />

ISDN S0 trunk con-<br />

CMS<br />

tive)nection (if active)<br />

3 CMS/CMA<br />

(see Table 2-<br />

37)<br />

ISDN S0 (not alwaysac-<br />

Via<br />

ISDN S0 trunk con-<br />

CMS<br />

tive)nection (if active)<br />

3 CMS/CMA<br />

(see Table 2-<br />

37)<br />

ISDN S0 (always<br />

active)<br />

Via<br />

ISDN S0 trunk con-<br />

– CMA<br />

nection<br />

2<br />

ISDN S0 (always<br />

active)<br />

Via<br />

ISDN S0 trunk con-<br />

– CMA<br />

nection<br />

2<br />

ISDN<br />

S2M Via<br />

ISDN S2M trunk con-<br />

– CMA<br />

nection<br />

2<br />

ISDN S2M Via<br />

ISDN S2M trunk con-<br />

– CMA<br />

nection<br />

2<br />

1 CMS is not necessary if the reference clock supplied by the CO is always available via the networking lines (not a transparent<br />

clock).<br />

2 CMA is not necessary if ADPCM conversion is not needed for <strong>HiPath</strong> Cordless Office (see Table 2-37).<br />

3 CMS is not necessary but is recommended for the following reasons: Although an Ethernet link is an asynchronous connection,<br />

buffer overflow/underflow can cause transmission errors. To avoid this, the clock difference between the master<br />

and the slave <strong>systems</strong> should be as small as possible so that the receive and send buffer can be read and addressed at<br />

the same speed on both sides. The more accurate the clock source in the relevant <strong>systems</strong>, the fewer the faults.<br />

P31003-H3570-Y100-4-7618, 2007-10-31<br />

<strong>HiPath</strong> <strong>3000</strong>/<strong>5000</strong> <strong>V7</strong>, System Description 2-79

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!