www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

A<br />

Low:<br />

Cement floor<br />

paving<br />

Impact sound<br />

Insulation layer<br />

(plus PE foil)<br />

Heat insulation<br />

Raw covering/<br />

concrete<br />

Plaster<br />

Low width and straight-lined:<br />

Floor paving<br />

Foil<br />

impact sound<br />

insulation<br />

Heat insulation<br />

Raw covering<br />

Cement floor<br />

paving<br />

m' = 92 kg/m2 Impact sound<br />

insulation values:<br />

0.2 mm PE foil<br />

25/20 mm<br />

MF boards<br />

s' = 8 MN/m 3<br />

30/25 mm<br />

MF boards<br />

s' = 6 MN/m 3<br />

Raw covering<br />

140 mm<br />

Insulation strips<br />

to compensate height<br />

�����<br />

isopact BG HRF<br />

Multi-component, asymmetric insulation for insulating<br />

connection lines of heaters<br />

g Approved by the building authorities<br />

g Stable<br />

With high tear-resistance HRF-PE fabric, the new<br />

isopact BG HRF stands up to even the hardest<br />

conditions at the building site, whereby the pipe<br />

is protected effectively against structure-borne<br />

contacts<br />

g Low<br />

Due to the newly developed floor insulation strips,<br />

isopact BG HRF provides a thermal conductance<br />

value of l R = 0.035 W/mK for the first time;<br />

at a full insulation effect, the height is reduced by<br />

14 mm in comparison to other insulation materials;<br />

even the 100 % models vanish in the heat insulation<br />

layer; the impact sound insulation can be laid<br />

throughout; excellent impact sound insulation<br />

values can be achieved; the danger of cracks in the<br />

floor paving is minimized<br />

g Asymmetrical<br />

The same insulation downwards against heat loss<br />

as with round-extruded insulation materials at<br />

minimum height<br />

g Flexible<br />

Due to its flexible character and an optimal buckling<br />

and bending characteristic, it can be easily pushed<br />

over bent connection lines of heaters; also has good<br />

nonslump properties in curves – the insulation<br />

strips remain where the heat loss has to be avoided:<br />

on the raw floor<br />

Comparative width Comparative width<br />

Stable due to highly rip-resistant HRF-PE fabric:<br />

Tear strength<br />

along 600 N/50 mm DIN 53354<br />

across 600 N/50 mm DIN 53354<br />

Elongation at break<br />

along 25 % DIN 53354<br />

across 15 % DIN 53354<br />

g High point elasticity and tear propagation<br />

resistance<br />

Twinskin design of woven HDPE-fabric with LDPE<br />

coating<br />

HDPE fabric<br />

LDPE coating<br />

Space saving insulation for floor areas<br />

g Low width<br />

Narrow, space-saving construction minimizes the<br />

breaks in the insulation layer in the floor construction;<br />

the danger of cracks in the floor paving is considerably<br />

reduced due to increased bending stress<br />

g Straight-line<br />

Due to the straight-lines side wall of isopact BG<br />

HRF, a matching connection is achieved to the<br />

adjacent isopact insulation as well as a heat and<br />

impact sound layer; cavities and uneven locations<br />

within the paved floor, as occur in round insulation,<br />

are avoided; the full buoyancy of the paving is<br />

maintained and the danger of cracks to the paving<br />

is reduced.<br />

g Excellent impact sound insulation values<br />

Even if a thoroughgoing laying of the impact sound<br />

insulation layer is not possible for large isopact<br />

sizes when the floor construction is low, there is an<br />

improvement of structure borne noise reduction of<br />

up to 38 dB when using isopact BG HRF in the floor<br />

construction<br />

Technical data<br />

Manufacturing process: welded bonding material<br />

Material: highly rip-resistant HRF-PE fabric<br />

and PE foam<br />

Thermal conductance l R = 0,035 W/mK<br />

acc. to DIN 52612 l = 0,035 W/mK*<br />

Temperature range (effective): -70 °c to +80 °c<br />

Reaction to fire (DIN 41<strong>02</strong>) B2, normal<br />

flammability<br />

Rod length 2 m<br />

Level of impact sound improvement ∆ L W, R = 38 dB<br />

3-component isopact design:<br />

Please request<br />

proof certificates!<br />

Fire classification<br />

acc. to DIN 41<strong>02</strong><br />

normal flammability<br />

* determined by internal test at the factory<br />

Strong outer skin made of highly<br />

tear-resistance HRF-PF fabric protects<br />

the pipe against mechanical influences<br />

Closed-cell PE as additional vapor<br />

barrier and heat insulation<br />

Closed-cell PE with calculated value<br />

0.035 W/mK guarantees perfect heat<br />

insulation to the bottom and excellent<br />

sound insulation values<br />

436 1006