07.01.2013 Views

02 - BTI - We know your business

02 - BTI - We know your business

02 - BTI - We know your business

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

1006<br />

�����<br />

Standard connection adapter<br />

Fits on standard pipe clamps with tapped thread<br />

The standard connection adapter can be screwed onto the welded tapped thread and can be delivered with the inner<br />

thread listed below. This provides you with a range of connection possibilities.<br />

weight Fits on Unit Item<br />

Connection IG kg/piece layered nut Pieces number<br />

M 16 0.09 M 8/M10 1 016146<br />

Socket1/2” 0.07 M 8/M10 1 016147<br />

M 16 0.09 M10/M12 1 016148<br />

Socket1/2” 0.08 M10/M12 1 016149<br />

Standard pipe clamp MS, heavy<br />

In two parts, galvanized with noise-insulation profile<br />

Design/Assembly:<br />

g Fire-protection tested by MPA Stuttgart, Otto-Graf-Institut; F30, F60, F90<br />

g Pipe clamps with locking screws<br />

g with connection M8/M10 round dia. 17 mm, M10/M12 round dia. 18 mm,<br />

M16 hex a/f 24, 1/2” round socket dia. 26.5 mm<br />

g Suitable for simple fixing using a connecting thread or<br />

Technical data:<br />

g Material S235JR<br />

g Galvanized acc. to DIN 50961<br />

g Noise protection for DIN 4109<br />

g Locking screws acc. to DIN 933, captive pendulum nut<br />

g Noise-insulation profile:<br />

Material: Rubber EPDM/SBR SILICONE<br />

Temperature resistance - 40 °c to +120 °c - 60 °c to +250 °c<br />

material thickness 6 mm 6 mm<br />

Building material class acc. to DIN 41<strong>02</strong> B2 B2<br />

1) Load details determined at a temperature load of up to 250 °c<br />

2) Limited by optical considerations<br />

double fixing using boreholes at the clamp shackles<br />

NOISE-<br />

PROTECTION<br />

acc. to DIN 4109<br />

Dimension F max. at 1) Live load 1) Live load 2)<br />

range material yield strength upright assembly suspended assembly<br />

mm kN kN kN<br />

22 – 57 12,375 8.25 2.50<br />

58 – 117 14,580 9.90 2.90<br />

121 – 275 23,100 15.40 3.40<br />

Max. permissible load for fire resistance<br />

Pipe<br />

clamping<br />

range<br />

MLAR/LAR/<br />

RbLei1) F30<br />

“F. resist.“ 30<br />

[kN]<br />

Perm. load<br />

[mm]<br />

“F. resist.“ 60<br />

[kN]<br />

64-89 3.40 2.50 1.30<br />

108-168 3.40 2.50 1.40<br />

177-368 3.40 2.50 1.60<br />

1) In some German states introduced with an altered name and partially<br />

different details from the building authorities as the line system regulation<br />

“F. resist.“ 90<br />

[kN]<br />

Fire tested<br />

Building<br />

Material class<br />

B2<br />

„Normal flammability“<br />

acc. to DIN 41<strong>02</strong><br />

with noise-insulation insert<br />

Connection: Tapped thread M8/M10 EPDM/SBR<br />

Clamping range Material: Screw H (min-max) A B S D weight Unit Item<br />

mm inch mm plugs mm mm mm mm mm kg/piece Pieces number<br />

20 – 25 1/2 25 x 3.0 M 8 x 30 56 – 61 30 103 79 10.5 0.254 25 016057<br />

26 – 30 3/4 25 x 3.0 M 8 x 30 65 – 69 30 111 87 10.5 0.267 25 016058<br />

31 – 36 1 25 x 3.0 M 8 x 30 70 – 75 30 116 92 10.5 0.280 25 016059<br />

38 – 45 1 1/4 25 x 3.0 M 8 x 30 77 – 84 30 124 100 10.5 0.301 25 016060<br />

47 – 51 1 1/2 25 x 3.0 M 8 x 30 86 – 90 30 132 108 10.5 0.315 25 016064<br />

53 – 57 25 x 3.0 M 8 x 30 92 – 96 30 138 114 10.5 0.336 25 016065<br />

58 – 64 2 30 x 3.0 M 8 x 30 97 – 103 30 144 119 10.5 0.393 25 016066<br />

www.<strong>BTI</strong>-GROUP.COM<br />

07<br />

C<br />

497

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!