07.01.2013 Views

02 - BTI - We know your business

02 - BTI - We know your business

02 - BTI - We know your business

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

WWW.bTI-gROUP.COM<br />

08<br />

C<br />

�����<br />

Fire protection sealing compound S 90<br />

FIRE PROTECTION<br />

Sealing layer forming fire protection sealing compound for S 90 wall and ceiling ducts of cables, cable looms<br />

and cable bearing systems acc. to DIN 41<strong>02</strong>, part 9<br />

Application areas:<br />

Walls made from:<br />

Masonry, concrete, steel concrete<br />

Ceilings made from:<br />

Concrete, steel concrete<br />

Minimum component length:<br />

15 cm each<br />

bulkhead strength:<br />

≥ 15 cm<br />

Max. bulkhead size:<br />

Wall and ceiling: ≤ 500 cm² or dia. 25 cm<br />

Other application areas:<br />

Especially suitable for sealing remaining apertures for<br />

later configuration, for sealing small joints in the fire<br />

protection system LBM 90 fire protection grout and for<br />

sealing small cable ducts<br />

Processing instructions:<br />

Minimum filling depth from every bulkhead side: 5 cm;<br />

of the remaining space can be filled with mineral<br />

rock of fire class A acc. to DIN 41<strong>02</strong>, melting point<br />

> 1000 °C; later configuration by closing the remaining<br />

joint with S 90 fire protection sealing compound is<br />

easily and quickly possible; shelf life: 9 months at<br />

+20 °C<br />

The “general planning permission” must be observed<br />

for secure application of the fire break in compliance<br />

with the permission. general planning permission for<br />

the fire break: Z-19.15-318<br />

Item Unit Designation Content<br />

number Pieces ml<br />

011617 1/12 Fire protection sealing compound S 90 310<br />

011618 10 LBM 90/S 90<br />

08-900 A/P 08900AA<br />

The details specified in this publication are based on our current <strong>know</strong>ledge and experience. Due to the abundance of possible processing and application influences this information does not release the processor from performing his<br />

618 own tests and trials. Legally binding assurance of certain characteristics or suitability for a concrete implementation objective can not be derived from this information.<br />