3GPP TS 25.331 version 12.3.0 Release 12<br />

1057<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information<br />

Element/Group name<br />

>>Number of additional<br />

timeslo<strong>ts</strong><br />

Need Multi Type and<br />

reference<br />

MP<br />

Integer(1..<br />

maxTS-1)<br />

>Timeslot list<br />

>>Additional timeslot list MP 1 to<br />

<br />

>>>CHOICE parameters MP<br />

>>>>Same as last<br />

>>>>>Timeslot number MP Timeslot<br />

Number<br />

10.3.6.84<br />

>>>>New parameters<br />

>>>>>Individual timeslot<br />

info<br />

MP<br />

>>>>>Code List MP 1..2<br />

>>>>>>Channelisation MP<br />

Code<br />

>>>>>> PLCCH Info CVno_DL_D<br />

PCH<br />

Individual<br />

timeslot<br />

info<br />

10.3.6.37<br />

Enumerate<br />

d((1/1),)(2/<br />

1),(2/2),(4/<br />

1)..(4/4),(8/<br />

1)..(8/8),(1<br />

6/1)..(16/1<br />

6))<br />

PLCCH<br />

Info<br />

10.3.6.50a<br />

Semantics<br />

description<br />

The timeslo<strong>ts</strong> used by<br />

the physical layer shall<br />

be timeslo<strong>ts</strong>:<br />

N mod maxTS<br />

(N+1) mod maxTS<br />

…<br />

(N+k) mod maxTS<br />

in that order, where N<br />

is the timeslot number<br />

in the First individual<br />

timeslot info and k the<br />

Number of additional<br />

timeslo<strong>ts</strong>.<br />

The additional timeslo<strong>ts</strong><br />

shall use the same<br />

parameters (e.g.<br />

channelisation codes,<br />

midamble shif<strong>ts</strong> etc.) as<br />

the first timeslot.<br />

The first instance of this<br />

parameter corresponds<br />

to the timeslot that shall<br />

be used second by the<br />

physical layer, the<br />

second to the timeslot<br />

that shall be used third<br />

and so on.<br />

This physical layer shall<br />

use the same<br />

parameters (e.g.<br />

channelisation codes,<br />

midamble shif<strong>ts</strong> etc.)<br />

for this timeslot as for<br />

the last one.<br />

Default is same as set<br />

of parameter values as<br />

assigned to last<br />

timeslot<br />

No_DL_DPCH<br />

Condition<br />

Explanation<br />

This IE is mandatory present for 1.28 Mcps TDD<br />

only in the case that Uplink Timeslo<strong>ts</strong> and Codes<br />

are assigned for UL DPCH and no DL DPCH is<br />

allocated to the UE.<br />