3GPP TS 25.331 version 12.3.0 Release 12<br />

1889<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

access<br />

capabilit<br />

y<br />

10.3.8.7<br />

13.4.11 INVALID_CONFIGURATION<br />

This variable indicates whether a received message contained an invalid configuration, by means of invalid values or<br />

invalid combinations of information elemen<strong>ts</strong>.<br />

Information Element/Group Need Multi Type and Semantics description<br />

name<br />

reference<br />

Invalid configuration MP Boolean TRUE: An invalid configuration<br />

has been detected.<br />

Set to FALSE when entering<br />

UTRA RRC connected mode.<br />

Set to FALSE when leaving<br />

UTRA RRC connected mode.<br />

13.4.11a LATEST_CONFIGURED_CN_DOMAIN<br />

This variable stores the CN-domain that was most recently configured to be used for ciphering and integrity protection.<br />

Information Element/Group<br />

name<br />

Need Multi Type and<br />

reference<br />

Latest configured CN domain OP CN domain<br />

identity<br />

10.3.1.1<br />

Semantics description<br />

Cleared when entering UTRA<br />

RRC connected mode when<br />

not stated otherwise in the<br />

procedure.<br />

Cleared when leaving UTRA<br />

RRC connected mode.<br />

13.4.11b LATEST_CONFIGURED_SRB_DELAY_AND_PC_PREAMBLE<br />

This variable stores the SRB delay and PC preamble to be used for establishing the DPCH after failure of hard<br />

handover, inter-RAT handover from UTRAN, or cell change order from UTRAN.<br />

Information Element/Group Need Multi Type and Semantics description<br />

name<br />

reference<br />

SRB delay OP Integer (0..7) Cleared when entering UTRA<br />

RRC connected mode when<br />

not stated otherwise in the<br />

procedure.<br />

PC preamble OP Integer (0..7) Cleared when entering UTRA<br />

RRC connected mode when<br />

not stated otherwise in the<br />

procedure.<br />

13.4.11c MBMS_ACTIVATED_SERVICES<br />

This variable stores the MBMS multicast services the UE has joined as well as the MBMS broadcast services the UE is<br />

interested to receive. Whenever the list of joined multicast services and/ or interested broadcast services changes, upper<br />

layers provide an indication upon which the UE shall update the variable accordingly. In case upper layers de-select an<br />

MBMS Selected Services, the UE shall remove the concerned service from the variable. Likewise, when upper layers<br />

select an MBMS Selected Services, the UE shall add the concerned service to the variable.<br />