28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

537<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

8.6.6.48 Secondary cell MIMO parameters<br />

If the IE "Secondary cell MIMO parameters" is included, the UE shall:<br />

1> Determine the value for the corresponding SECONDARY_CELL_MIMO_STATUS variable and take the<br />

corresponding actions as described in subclause 8.5.57;<br />

1> determine the configuration of "TSN field extension" for MAC-ehs entity as specified in subclause 8.5.60.<br />

NOTE:<br />

This subclause applies to FDD only.<br />

8.6.6.49 Uplink Secondary Cell Info FDD (FDD only)<br />

If the IE "Uplink Secondary Cell Info FDD" is included and the UE will be in CELL_DCH state after completion of this<br />

procedure, the UE shall:<br />

1> if the CHOICE "Configuration info" is set to "New configuration":<br />

2> if the IE "Secondary serving E-DCH cell info" is included in the IE "Uplink Secondary Cell Info FDD":<br />

3> if the IE "Frequency info" included in the IE "Secondary E-DCH info common" is different from the<br />

stored frequency info:<br />

4> stop intra-frequency and inter-frequency measurement reporting on the downlink frequency associated<br />

with the current secondary uplink frequency. Each stopped measurement is restarted when a<br />

MEASUREMENT CONTROL message is received with the corresponding measurement identity.<br />

3> store the IE "Secondary serving E-DCH cell info", replacing any stored IE "Secondary serving E-DCH<br />

cell info".<br />

2> if the IE "Secondary E-DCH info common" is included in the IE "Uplink Secondary Cell Info FDD":<br />

3> store the IE "Secondary E-DCH info common", replacing any stored IE "Secondary E-DCH info<br />

common".<br />

2> if the IE "Downlink information per radio link list on secondary UL frequency" is included in the IE "Uplink<br />

Secondary Cell Info FDD":<br />

3> act as specified in subclause 8.6.6.3b.<br />

2> determine the value for the IMPLICIT_GRANT variable and take the corresponding actions as described in<br />

subclause 8.5.85;<br />

1> if the CHOICE "Configuration info" is set to "Continue" and the UE has any stored IE "Secondary E-DCH info<br />

common":<br />

2> keep the stored IE "Secondary serving E-DCH cell info" and IE "Secondary E-DCH info common".<br />

1> if SECONDARY_CELL_E_DCH_TRANSMISSION variable is set to TRUE:<br />

2> if the IE "UARFCN downlink (Nd)" is present in the first IE "Downlink Secondary Cell Info FDD" and is<br />

different from the stored "Frequency info" in the IE "Secondary E-DCH info common":<br />

3> UE behaviour is unspecified.<br />

2> if the variable SECONDARY_CELL_E_DCH_TRANSMISSION was previously set to FALSE; or<br />

2> if the IE "Frequency info" included in the IE "Secondary E-DCH info common" is different from the<br />

previously stored frequency info:<br />

3> continue inter-frequency measurement reporting on the downlink frequency associated with the new<br />

secondary uplink frequency. The UE shall not require compressed mode to perform the measurement,<br />

regardless of the activation status of secondary uplink frequency.<br />

If the IE "Uplink Secondary Cell Info FDD" is not included and the UE has any stored IE "Secondary E-DCH info<br />

common", the UE shall:<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!