28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

449<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

When the variable HS_DSCH_RECEPTION is set to TRUE the UE shall:<br />

1> use the value of the variable H_RNTI as UE identity in the HS-SCCH reception procedure in the physical layer.<br />

In FDD and 1.28 Mcps TDD, if the IE "New H-RNTI" is included and the UE will be in CELL_FACH state after<br />

completion of this procedure, the UE shall:<br />

1> store the value in the variable H_RNTI;<br />

1> determine the value for the HS_DSCH_RECEPTION_CELL_FACH_STATE variable and take the<br />

corresponding actions as described in subclause 8.5.36.<br />

1> for 1.28 Mcps TDD, If the IE "Treset Usage Indicator" has been stored:<br />

2> stop using all configured Treset timer [15].<br />

When the variable HS_DSCH_RECEPTION_CELL_FACH_STATE is set to TRUE the UE shall:<br />

1> use the value of the variable H_RNTI as UE identity in the HS-SCCH reception procedure in the physical layer.<br />

When an entry in the variable SECONDARY_CELL_HS_DSCH_RECEPTION is set to TRUE the UE shall:<br />

1> use the value of the variable H_RNTI associated with the corresponding secondary serving HS-DSCH cell as UE<br />

identity in the HS-SCCH reception procedure in the physical layer on that cell.<br />

In FDD and 1.28 Mcps TDD, if the IE "New H-RNTI" is included and the UE will be in CELL_PCH state after<br />

completion of this procedure, the UE shall:<br />

1> store the value in the variable H_RNTI.<br />

1> for 1.28 Mcps TDD, If the IE "Treset Usage Indicator" has been stored:<br />

2> stop using all configured Treset timer [15].<br />

8.6.3.2 UTRAN DRX Cycle length coefficient<br />

If the IE "UTRAN DRX cycle length coefficient" is present, the UE shall use it to calculate the UTRAN DRX cycle<br />

length, according to the following:<br />

1> start timer T319 using the IE "Time for DRX cycle 2" value;<br />

1> store IE "DRX cycle length coefficient";<br />

1> set k to the value of the IE "DRX cycle length coefficient 2";<br />

1> store the result of MAX(2 k, PBP), where PBP is the Paging Block Periodicity, as the DRX cycle length.<br />

The UE shall determine i<strong>ts</strong> connected mode paging occasions and PICH monitoring occasions in the same way as for<br />

idle mode, according to [4].<br />

The DRX cycle length to use in connected mode is defined in [4].<br />

8.6.3.3 Generic state transition rules depending on received information elemen<strong>ts</strong><br />

The IE "RRC State Indicator" indicates the state the UE shall enter. The UE shall enter the state indicated by the IE<br />

"RRC State Indicator" even if the received message includes other IEs relevant only for states other than indicated by<br />

the IE "RRC State Indicator". E.g. if the RRC state indicator is set to CELL_FACH while other IEs provide information<br />

about a configuration including dedicated channels, the UE shall enter CELL_FACH state. If however the UE has no<br />

information about the configuration corresponding to the state indicated by the IE "RRC State Indicator", it shall<br />

consider the requested configuration as invalid.<br />

The UE shall, if the IE "RRC State Indicator" in the received message has the value:<br />

1> "CELL_FACH":<br />

2> enter CELL_FACH state as dictated by the procedure governing the message received.<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!