3GPP TS 25.331 version 12.3.0 Release 12<br />

1131<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

10.3.7.10 HCS Cell re-selection information<br />

Information Element/Group<br />

name<br />

Need Multi Type and<br />

reference<br />

Penalty_time MD Integer(0,<br />

10, 20, 30,<br />

40, 50, 60)<br />

Temporary_offse<strong>ts</strong><br />

CV-Penalty<br />

used<br />

>Temporary_offset1 MP Integer(3, 6,<br />

9, 12, 15, 18,<br />

>Temporary_offset2<br />

CV-FDD-<br />

Quality-<br />

Measure<br />

21, inf)<br />

Integer(2, 3,<br />

4, 6, 8, 10,<br />

12, inf)<br />

Semantics description<br />

Default value is 0 which<br />

means = not used<br />

In seconds<br />

[dB]<br />

[dB]<br />

Penalty used<br />

FDD-Quality-Measure<br />

Condition<br />

Explanation<br />

This IE is not needed if the IE "Penalty time" equals<br />

"not used", else it is mandatory present.<br />

This IE is not needed if the IE "Cell selection and<br />

reselection quality measure" has the value CPICH<br />

RSCP, otherwise the IE is mandatory present. This<br />

conditional presence is implemented in ASN.1 by the<br />

use of a specific RSCP and EcN0 variant of<br />

10.3.7.10.<br />

10.3.7.11 HCS neighbouring cell information<br />

Information Element/Group Need Multi Type and Semantics description<br />

name<br />

reference<br />

HCS_PRIO MD Integer (0..7) Default value = 0<br />

Qhcs MD Qhcs Default value = 0<br />

10.3.7.54a<br />

HCS Cell Re-selection<br />

Information<br />

MP<br />

HCS Cell<br />

Re-selection<br />

Information<br />

10.3.7.10<br />

10.3.7.12 HCS Serving cell information<br />

Information Element/Group Need Multi Type and Semantics description<br />

name<br />

Reference<br />

HCS_PRIO MD Integer (0..7) Default value = 0<br />

Qhcs MD Qhcs Default value = 0<br />

10.3.7.54a<br />

T CRmax MD Enumerated(<br />

not used, 30,<br />

60, 120, 180,<br />

240)<br />

[s]<br />

Default value is not used<br />

N CR<br />

T CrmaxHyst<br />

CV-UE<br />

speed<br />

detector<br />

CV-UE<br />

speed<br />

detector<br />

Integer(1..16<br />

)<br />

Enumerated(<br />

not used, 10,<br />

20, 30, 40,<br />

50, 60, 70)<br />

Default value = 8<br />

[s]<br />

UE Speed detector<br />

Condition<br />

Explanation<br />

This IE is not needed if T Crmax equals 'not used', else it<br />

is mandatory present.<br />