3GPP TS 25.331 version 12.3.0 Release 12<br />

2097<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

1> if the other RAT is E-UTRA:<br />

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for one or several E-<br />

UTRA cells on any of the frequencies considered in that inter-RAT measurement and that are not included in<br />

the blacklist:<br />

3> if any of those E-UTRA cells is not stored into the variable TRIGGERED_3C_EVENT:<br />

4> store the E-UTRA cells that triggered the event and that were not previously stored in the variable<br />

TRIGGERED_3C_EVENT into that variable;<br />

4> send a measurement report with IEs set as below:<br />

5> set in "E-UTRA event resul<strong>ts</strong>": "inter-RAT event identity" to "3c", and "E-UTRA carrier<br />

frequency" and "Physical cell identity" to the EARFCN and physical cell identity of the cells that<br />

triggered the event (best one first);<br />

5> set the IE "E-UTRA measured resul<strong>ts</strong>" according to subclause 8.6.7.5.<br />

2> if equation 2 is fulfilled for a cell that is stored in the variable TRIGGERED_3C_EVENT:<br />

3> remove that cell from the variable TRIGGERED_3C_EVENT.<br />

Triggering condition:<br />

Equation 1:<br />

M + CIO ≥T<br />

+ H<br />

Other RAT<br />

Other RAT<br />

Other RAT<br />

3c<br />

/2<br />

The variables in the formula are defined as follows:<br />

M Other RAT is the measurement quantity for the cell of the other system. M Other RAT is expressed in dBm.<br />

CIO Other RAT is the cell individual offset for the cell of the other system.<br />

T Other RAT is the absolute threshold that applies for the other system in that measurement.<br />

H 3c is the hysteresis parameter for event 3c.<br />

Leaving triggered state condition:<br />

Equation 2:<br />

M<br />

Other RAT<br />

+ CIO<br />

Other RAT<br />

< T<br />

Other RAT<br />

−H<br />

3c<br />

/2<br />

The variables in the formula are defined as follows:<br />

M Other RAT is the measurement quantity for the cell of the other system. M Other RAT is expressed in dBm.<br />

CIO Other RAT is the cell individual offset for the cell of the other system.<br />

T Other RAT is the absolute threshold that applies for the other system in that measurement.<br />

H 3c is the hysteresis parameter for event 3c.<br />

14.3.1.4 Event 3d: Change of best cell in other system<br />

When an inter-RAT measurement configuring event 3d is set up, the UE shall:<br />

1> create a variable BEST_CELL_3D_EVENT related to that measurement;<br />

1> delete this variable when the measurement is released.<br />

When event 3d is configured in the UE within a measurement, the UE shall:<br />