28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

2108<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

- Bad CRC = the number of bad CRC that is required within the latest "Total CRC" received CRCs for the event<br />

to be triggered.<br />

- Pending after trigger = a new event can not be triggered until "Pending after trigger" CRCs have been received,<br />

When a DCH is established, the UE shall begin to count the number of bad CRCs within the last "Total CRC" received<br />

CRCs. No event can be triggered until at least "Total CRC" CRCs have been received. For each new received CRC, the<br />

UE shall compare the number of bad CRCs within the latest "Total CRC" received CRCs with the parameter "Bad<br />

CRC". An event shall be triggered if the number of bad CRCs is equal or larger than "Bad CRC".<br />

At the time when the event is triggered a pending time after trigger timer is started with the length of "Pending after<br />

trigger" CRCs. A new event can not be triggered until Pending after trigger" CRCs have been received. When Pending<br />

after trigger" CRCs have been received the event evaluation start again and a new event can be triggered.<br />

Total CRC<br />

Total CRC<br />

Total CRC<br />

Total CRC<br />

Good CRC<br />

Bad CRC<br />

No repor<strong>ts</strong><br />

No repor<strong>ts</strong><br />

Report 1 Report 2<br />

Pending after trigger Pending after trigger<br />

Report 3<br />

Figure 14.5.2.1-1: Event triggered CRC error reporting<br />

14.6 UE internal measuremen<strong>ts</strong><br />

14.6.1 UE internal measurement quantities<br />

For UE internal measuremen<strong>ts</strong> the following measurement quantities exist:<br />

1. UE transmission (Tx) power, for TDD measured on a timeslot basis.<br />

2. UE received signal strength power (RSSI).<br />

3. UE Rx-Tx time difference (FDD only).<br />

4. T ADV (1.28 Mcps TDD).<br />

14.6.2 UE internal measurement reporting even<strong>ts</strong><br />

In the Measurement reporting criteria field in the Measurement Control messages, the UTRAN notifies the UE of which<br />

even<strong>ts</strong> should trigger a measurement report. UE internal measurement reporting even<strong>ts</strong> that can trigger a report are<br />

given below. The reporting even<strong>ts</strong> are marked with vertical arrows in the figures below. All even<strong>ts</strong> can be combined<br />

with time-to-trigger.<br />

NOTE:<br />

The reporting even<strong>ts</strong> are numbered 6A, 6B, 6C,.. where 6 denotes that the event belongs to the type UE<br />

internal measuremen<strong>ts</strong>.<br />

When one measurement identity corresponds to multiple internal even<strong>ts</strong> with identical event identities, the UE<br />

behaviour is not defined.<br />

14.6.2.1 Reporting event 6A: The UE Tx power becomes larger than an absolute<br />

threshold<br />

When a UE internal measurement configuring event 6a is set up, the UE shall:<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!