3GPP TS 25.331 version 12.3.0 Release 12<br />

2066<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

5> stop the reporting interval timer;<br />

5> set the IE "Periodical reporting running" in the variable TRIGGERED_1J_EVENT to FALSE.<br />

Equation 1 (Triggering condition for pathloss)<br />

10⋅<br />

LogMNew+<br />

CIONew≤10⋅<br />

LogMInAS+<br />

CIOInAS−H<br />

1j<br />

/2,<br />

Equation 2 (Triggering condition for all the other measurement quantities)<br />

10⋅<br />

LogM<br />

New+<br />

CIONew≥10⋅<br />

LogMInAS+<br />

CIOInAS+<br />

H1j<br />

/2,<br />

Equation 3 (Leaving triggering condition for pathloss)<br />

10⋅<br />

LogM<br />

New+<br />

CIONew><br />

10⋅<br />

LogMInAS+<br />

CIOInAS+<br />

H1j<br />

/2,<br />

Equation 4 (Leaving triggering condition for all the other measurement quantities)<br />

10⋅<br />

LogMNew+<br />

CIONew<<br />

10⋅<br />

LogMInAS+<br />

CIOInAS−H<br />

1j<br />

/2,<br />

The variables in the formula are defined as follows:<br />

M New is the measurement result of the cell not included in the E-DCH active set but included in DCH active set.<br />

CIO New is the individual cell offset for the cell not included in the E-DCH active set but included in DCH active set<br />

becoming better than the cell in the E-DCH active set if an individual cell offset is stored for that cell. Otherwise<br />

it is equal to 0.<br />

For pathloss:<br />

M InAS is the measurement result of the cell in the E-DCH active set with the highest measurement result.<br />

For other measurement quantities:<br />

M InAS is the measurement result of the cell in the E-DCH active set with the lowest measurement result.<br />

CIO InAS is the individual cell offset for the cell in the E-DCH active set that is becoming worse than the new cell.<br />

H 1J is the hysteresis parameter for the event 1J.<br />

If the measurement resul<strong>ts</strong> are pathloss or CPICH-Ec/No then M New and M inAS are expressed as ratios.<br />

If the measurement result is CPICH-RSCP then M New and M inAS are expressed in mW.<br />

Measurement<br />

quantity<br />

P CPICH 1<br />

P CPICH 2<br />

P CPICH 3<br />

P CPICH 4<br />

Reporting<br />

event 1J<br />

Reporting<br />

event 1J<br />

Time<br />

Figure 14.1.2.7-1 [Informative]: A primary CPICH that is not included in the E-DCH active set but<br />

included in DCH active set becomes better than a primary CPICH that is in the E-DCH active set<br />

ETSI