28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3GPP TS 25.331 version 12.3.0 Release 12<br />

1141<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Clause 0<br />

Clause 1<br />

Clause 2<br />

Clause 3<br />

Clause 4<br />

Clause 5<br />

Clause 6<br />

Condition<br />

Explanation<br />

This IE is mandatory present if the IE "Inter frequency<br />

event identity" is set to 2b, 2d, or 2f, otherwise the IE<br />

is not needed.<br />

This IE is mandatory present if the IE "Inter frequency<br />

event identity" is set to 2a, 2b, 2c or 2e, otherwise the<br />

IE is not needed<br />

This IE is mandatory present if the IE "Inter-frequency<br />

event identity" is set to 2a, 2b, 2d or 2f, otherwise the<br />

IE is not needed.<br />

This IE is optional if the IE "Inter frequency event<br />

identity" is set to 2b, 2d, or 2f. Otherwise the IE is not<br />

needed.<br />

Note that in order to align with the ASN.1, this IE is<br />

always included when the IE “Delta Threshold non used<br />

frequency“ is present, but the value shall be ignored if the<br />

"Inter-frequency event identity" is not set to 2b, 2d or<br />

2f.<br />

This IE is optional if the IE "Inter frequency event<br />

identity" is set to 2a, 2b, 2c or 2e. Otherwise the IE is<br />

not needed.<br />

This IE is optional if the IE "Triggering Condition nonused<br />

frequency detected cells" is present. Otherwise<br />

the IE is not needed.<br />

This IE is optional if the IE "Inter frequency event<br />

identity" is set to 2g. Otherwise the IE is not needed.<br />

10.3.7.20 Inter-frequency measurement system information<br />

Information Element/Group<br />

name<br />

Need Multi Type and<br />

reference<br />

Inter-frequency cell info list OP Interfrequency<br />

cell info list<br />

10.3.7.13<br />

Inter-frequency RACH reporting OP<br />

Interfrequency<br />

information<br />

RACH<br />

reporting<br />

information<br />

10.3.7.20a<br />

Semantics description<br />

Version<br />

REL-6<br />

10.3.7.20a<br />

Inter-frequency RACH reporting information<br />

Contains the reporting configuration information for an inter-frequency measurement report, which is sent on the<br />

RACH.<br />

Information Need Multi Type and reference Semantics Version<br />

Element/Group name<br />

description<br />

CHOICE mode MP REL-6<br />

>FDD<br />

REL-6<br />

>> Inter-frequency MP<br />

Enumerated(CPICH<br />

REL-6<br />

RACH reporting<br />

quantity<br />

Ec/N0, CPICH<br />

RSCP)<br />

>TDD<br />

REL-6<br />

>>Reporting quantity list MP 1 to 2 REL-6<br />

>>> Inter-frequency<br />

RACH reporting<br />

quantity<br />

MP<br />

Enumerated(Primary<br />

CCPCH RSCP)<br />

REL-6<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!