28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3GPP TS 25.331 version 12.3.0 Release 12<br />

1183<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information<br />

Element/Group name<br />

>>Maximum number of<br />

reported cells<br />

>Report all virtual active<br />

set cells + cells within<br />

monitored set and/or<br />

detected set on non-used<br />

frequency<br />

>>Maximum number of<br />

reported cells<br />

Need Multi Type and<br />

reference<br />

MP<br />

MP<br />

Integer(1..12<br />

)<br />

Enumerated<br />

(virtual/activ<br />

e set cells+1,<br />

virtual/active<br />

set cells+2,<br />

….,<br />

virtual/active<br />

set cells+6)<br />

Semantics<br />

description<br />

measuremen<strong>ts</strong>, the UE<br />

shall report cells within<br />

the virtual active set<br />

and/or monitored set on<br />

non-used frequency.<br />

This choice is not valid<br />

for inter-RAT or intrafrequency<br />

measuremen<strong>ts</strong><br />

Version<br />

REL-10<br />

REL-10<br />

NOTE 1: For Inter-frequency reporting even<strong>ts</strong> 2D and 2F, only CHOICE "Report cells within active set" is valid.<br />

10.3.7.62 Reporting information for state CELL_DCH<br />

Information Element/Group<br />

name<br />

Intra-frequency reporting<br />

quantity<br />

Need Multi Type and<br />

reference<br />

MP<br />

Intrafrequency<br />

reporting<br />

quantity<br />

10.3.7.41<br />

Measurement Reporting Mode MP Measuremen<br />

t Reporting<br />

Mode<br />

10.3.7.49<br />

CHOICE report criteria<br />

>Intra-frequency measurement<br />

reporting criteria<br />

>Periodical reporting criteria<br />

MP<br />

Intrafrequency<br />

measuremen<br />

t reporting<br />

criteria<br />

10.3.7.39<br />

Periodical<br />

reporting<br />

criteria<br />

10.3.7.53<br />

Semantics description<br />

This IE may only contain<br />

measurement even<strong>ts</strong> from 1A<br />

to 1I, but not measurement<br />

event 1J.<br />

10.3.7.63 SFN-SFN observed time difference<br />

Information<br />

Element/Group name<br />

CHOICE type<br />

>Type 1<br />

Need Multi Type and<br />

reference<br />

MP<br />

Integer(0..<br />

9830399)<br />

Integer(0..<br />

3276799)<br />

Semantics description<br />

According to T1_SFN-SFN_TIME in<br />

[19] and [20].<br />

For FDD and 3.84 Mcps TDD and 7.68<br />

Mcps TDD:<br />

6946816 spare values are needed.<br />

For 1.28 Mcps TDD:<br />

13500416 spare values are needed.<br />

Rel-4<br />

Version<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!