28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

1142<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information<br />

Element/Group name<br />

Inter-frequency RACH<br />

reporting threshold<br />

Maximum number of<br />

inter-frequency RACH<br />

reporting cells<br />

Need Multi Type and reference Semantics<br />

description<br />

MP Integer(-115..0) Ranges used<br />

depend on<br />

measurement<br />

quantity.<br />

CPICH Ec/No -<br />

24..0dB<br />

CPICH/Primary<br />

CCPCH RSCP -<br />

115..-25dBm.<br />

MP Integer(1..8) Indicates the total<br />

number for all nonused<br />

frequencies<br />

Version<br />

REL-6<br />

REL-6<br />

10.3.7.21 Inter-frequency reporting quantity<br />

Information Element/Group Need Multi Type and Semantics description<br />

name<br />

reference<br />

UTRA Carrier RSSI MP Boolean TRUE means report is<br />

requested.<br />

Frequency quality estimate MP Boolean TRUE means that report is<br />

requested.<br />

This parameter is not used in<br />

this release and should be set<br />

to FALSE. It shall be ignored<br />

by the UE.<br />

Non frequency related cell<br />

reporting quantities<br />

MP<br />

Cell<br />

reporting<br />

quantities<br />

10.3.7.5<br />

10.3.7.22 Inter-frequency SET UPDATE<br />

NOTE 1: Only for FDD.<br />

This information makes it possible to use even<strong>ts</strong> defined for Intra-frequency measurement within the same non-used<br />

frequency for Inter-frequency measurement reporting criteria.<br />

Information Element/group<br />

name<br />

Need Multi Type and<br />

reference<br />

UE autonomous update mode MP Enumerated<br />

(On with no<br />

reporting)<br />

Semantics description<br />

Required for backwards<br />

compatibility with a UE not<br />

supporting this revision of the<br />

standard<br />

10.3.7.23 Inter-RAT cell info list<br />

Contains the information for the list of measurement objec<strong>ts</strong> for an inter-RAT measurement.<br />

Information Element/Group<br />

name<br />

Need Multi Type and<br />

reference<br />

CHOICE Inter-RAT cell removal MP<br />

>Remove all inter-RAT cells<br />

>Remove some inter-RAT cells<br />

>>Removed inter-RAT cells MP 1 to<br />

<br />

>>>Inter-RAT cell id MP Integer(0 ..<br />

- 1)<br />

>Remove no inter-RAT cells<br />

Semantics<br />

description<br />

(no data)<br />

(no data)<br />

Version<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!