3GPP TS 25.331 version 12.3.0 Release 12<br />

106<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

8.1.1.6.20 System Information Block type 20<br />

If the cell is not operating in MBSFN mode according to subclause 8.1.1.6.3, the UE shall:<br />

1> if the IE "HNB Name" is present:<br />

2> forward the content of IE "HNB Name" to the upper layers.<br />

8.1.1.6.21 System Information Block type 21<br />

The EAB capable UE should store all relevant IEs included in this system information block. If the IE "EAB<br />

Parameters" is included, the EAB capable UE shall:<br />

1> if the IE "EAB Parameters For All" is included in the IE "EAB Parameters":<br />

2> select the IE "EAB Parameters For All".<br />

1> else:<br />

2> select the entry in the IE "EAB Parameters Per PLMN List" in the IE "EAB Parameters" corresponds to the<br />

PLMN chosen by the UE.<br />

1> if in idle mode:<br />

2> if the IE "CS Domain Specific EAB parameters" or the IE "Common EAB parameters" is included in the<br />

selected Domain Specific EAB Parameters:<br />

3> act on the IE "EAB Access Class Barred List" when initiating RRC Connection establishment to send an<br />

INITIAL DIRECT TRANSFER message to the CS domain, if upper layers indicate that the connection<br />

request is subject to EAB and the UE belongs to the category of UEs as indicated in the IE "EAB<br />

Category".<br />

2> if the IE "PS Domain Specific EAB parameters" or the IE "Common EAB parameters" is included in the<br />

selected Domain Specific EAB Parameters:<br />

3> act on the IE "EAB Access Class Barred List" when initiating RRC Connection establishment to send an<br />

INITIAL DIRECT TRANSFER message to the PS domain, if upper layers indicate that the connection<br />

request is subject to EAB and the UE belongs to the category of UEs as indicated in the IE "EAB<br />

Category".<br />

1> if in connected mode:<br />

2> store the selected Domain Specific EAB Parameters to the variable "EAB_PARAM" upon transition to RRC<br />

connected and maintain the variable until it is cleared, the PLMN chosen by the UE is changed or the RRC<br />

connection is released.<br />

2> if the IE "CS Domain Specific EAB parameters" or the IE "Common EAB parameters" is included in the<br />

stored Domain Specific EAB Parameters in variable "EAB_PARAM":<br />

3> act on the IE "EAB Access Class Barred List" when initiating an INITIAL DIRECT TRANSFER<br />

message to the CS domain, if upper layers indicate that the connection request is subject to EAB and the<br />

UE belongs to the category of UEs as indicated in the IE "EAB Category" and signalling connection to<br />

the PS domain is already established.<br />

2> if the IE "PS Domain Specific EAB parameters" or the IE "Common EAB parameters" is included in the<br />

stored Domain Specific EAB Parameters in variable "EAB_PARAM":<br />

3> act on the IE "EAB Access Class Barred List" when initiating an INITIAL DIRECT TRANSFER<br />

message to the PS domain, if upper layers indicate that the connection request is subject to EAB and the<br />

UE belongs to the category of UEs as indicated in the IE "EAB Category" and signalling connection to<br />

the CS domain is already established.<br />

8.1.1.6.22 System Information Block type 22<br />

The UE should store all relevant IEs included in this system information block.<br />