3GPP TS 25.331 version 12.3.0 Release 12<br />

1283<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information Element/Group<br />

name<br />

Need Multi Type and<br />

reference<br />

>CPICH RSCP MP Integer(0..<br />

91)<br />

>CPICH Ec/N0 MP Integer(0..<br />

49)<br />

Logged Measuremen<strong>ts</strong> Intra<br />

Frequency Neighbouring Cells<br />

list<br />

OP 1..<br />

MaxnumLogge<br />

dMeas<br />

>Primary CPICH info MP Primary<br />

CPICH info<br />

10.3.6.60<br />

>CPICH RSCP MP Integer(0..<br />

91)<br />

>CPICH Ec/N0 MP Integer(0..<br />

49)<br />

Logged Measuremen<strong>ts</strong> Inter<br />

Frequency list<br />

OP 1..<br />

MaxNumFDDF<br />

reqs<br />

>Frequency Info MP Frequency<br />

Info<br />

10.3.6.36<br />

> Logged Measuremen<strong>ts</strong> Interfrequency<br />

Neighbouring Cells<br />

list<br />

MP<br />

1..MaxnumLog<br />

gedMeas<br />

>>Primary CPICH info MP Primary<br />

CPICH info<br />

10.3.6.60<br />

>>CPICH RSCP MP Integer(0..<br />

91)<br />

>>CPICH Ec/N0 MP Integer(0..<br />

49)<br />

Semantics description<br />

CPICH RSCP of the<br />

serving Cell, when<br />

available<br />

In dBm. According to<br />

CPICH_RSCP_LEV in<br />

[19].<br />

Thirty-six spare values<br />

are needed.<br />

CPICH Ec/N0 of the<br />

serving Cell, when<br />

available<br />

In dB. According to<br />

CPICH_Ec/No in [19].<br />

Fourteen spare values<br />

are needed.<br />

Measuremen<strong>ts</strong> done on<br />

neighbouring cells<br />

In dBm. According to<br />

CPICH_RSCP_LEV in<br />

[19].<br />

Thirty-six spare values<br />

are needed.<br />

CPICH Ec/N0 of the<br />

serving Cell, when<br />

available<br />

In dB. According to<br />

CPICH_Ec/No in [19].<br />

Fourteen spare values<br />

are needed.<br />

Measuremen<strong>ts</strong> done on<br />

neighbouring cells<br />

In dBm. According to<br />

CPICH_RSCP_LEV in<br />

[19].<br />

Thirty-six spare values<br />

are needed.<br />

CPICH Ec/N0 of the<br />

serving Cell, when<br />

available<br />

Version<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

REL-10<br />

Logged Measuremen<strong>ts</strong> Inter-<br />

RAT Neighbour cells list<br />

>Logged Measuremen<strong>ts</strong> E-<br />

UTRA frequency list<br />

OP<br />

OP 1..<br />

MaxNumEUT<br />

RAFreqs<br />

In dB. According to<br />

CPICH_Ec/No in [19].<br />

Fourteen spare values<br />

are needed.<br />

REL-10<br />

REL-10<br />

ETSI