28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

533<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

2> if MAC-ehs is not configured:<br />

3> the UE behaviour is undefined.<br />

NOTE:<br />

This subclause applies to FDD and 1.28 Mcps TDD only.<br />

8.6.6.42 UL 16QAM settings<br />

If the IE "UL 16QAM settings" is included, the UE shall:<br />

1> indicate to lower layers to operate in 16QAM mode, using the parameters contained in the IE.<br />

8.6.6.42b<br />

UL 64QAM settings<br />

If the IE "UL 64QAM settings" is included, the UE shall:<br />

1> indicate to lower layers to operate in 64QAM mode, using the parameters contained in the IE;<br />

1> if MAC-i/is not configured:<br />

2> the UE behaviour is unspecified.<br />

8.6.6.43 Multi-frequency Info (1.28 Mcps TDD only)<br />

Upon reception of the IE "Multi-frequency info", the UE shall:<br />

1> If the IE "Second Frequency info" is included:<br />

2> act as specified in section 8.6.6.1.<br />

1> If the IE "FPACH Frequency info" is included:<br />

2> store the FPACH frequency indicated in the IE "FPACH Frequency info".<br />

1> else:<br />

2> use the primary frequency as FPACH frequency.<br />

1> If the IE "UpPCH Position Info" is included:<br />

2> store and use the UpPCH position indicated by the IE "UpPCH Positon Info ". The calculation of the uplink<br />

access position is described in [33].<br />

1> else:<br />

2> use the UpPTS as the default UpPCH position.<br />

8.6.6.44 Void<br />

8.6.6.45 Downlink Secondary Cell Info FDD<br />

In the following, any information in the "Downlink Secondary Cell Info FDD" is stored in the first entry of the variable<br />

DOWNLINK_SECONDARY_CELL_INFO. Any first (respectively second) IE "Downlink Secondary Cell Info FDD"<br />

in the "Additional downlink secondary cell info list FDD" IE, is stored in the second (respectively third) entry of the<br />

variable DOWNLINK_SECONDARY_CELL_INFO. Any first (respectively second, third and fourth) IE "Downlink<br />

secondary Cell Info FDD" in the "Additional downlink secondary cell info list FDD 2" IE, is stored in the fourth<br />

(respectively fifth, sixth and seventh) entry of the variable DOWNLINK_SECONDARY_CELL_INFO.<br />

If the i-th IE "Downlink Secondary Cell Info FDD" is not included and the UE has a stored i-th entry in the<br />

DOWNLINK_SECONDARY_CELL_INFO variable, the UE shall:<br />

1> clear the stored i-th entry in the DOWNLINK_SECONDARY_CELL_INFO variable.<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!