3GPP TS 25.331 version 12.3.0 Release 12<br />

601<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

1> set each pattern sequence to the variable DCH_MOPS_IDENTITY according to the IE "Pattern sequence<br />

identifier";<br />

1> update into the variable DCH_MOPS_IDENTITY the configuration information defined by IE group"<br />

Measurement occasion pattern sequence parameters";<br />

1> after the instant in which the message is to be executed without the IE "Activation time", or at the beginning of<br />

the frame indicated by IE “Activation time” as specified in subclause 8.6.3.1:<br />

2> activate the stored pattern sequence corresponding to each IE "Pattern sequence identifier" for which the<br />

"Status Flag" in the variable DCH_MOPS_IDENTITY is set to "activate"; and<br />

2> calculate the concerned CELL_DCH measurement occasion as specified in subclause 8.5.11a, and start the<br />

measurement at the frame calculated CELL_DCH measurement occasion.<br />

8.6.7.27 Frequency index list for enhanced measurement<br />

If the IE "Frequency index list for enhanced measurement" is received by the UE, the UE shall:<br />

1> if prior to the reception of the message, any of the variables "Adjacent frequency info", "Inter-band frequency<br />

info" or "Frequency info list for enhanced measurement" is stored in CELL_INFO_LIST, then for each of the<br />

stored variables:<br />

2> stop all inter-frequency measurement reporting on the cells that belong to the frequency derived from the<br />

stored variable. Each stopped measurement is restarted when a MEASUREMENT CONTROL message is<br />

received with the corresponding measurement identity.<br />

2> clear the stored variable.<br />

1> for each of the IE "Frequency index for enhanced measurement" included in the IE "Frequency index list for<br />

enhanced measurement":<br />

2> extract the frequency information of the element contained in the IE "New inter-frequency cells" that is<br />

indexed by the IE "Frequency index for enhanced measurement";<br />

2> store this frequency information in the variable "Frequency info list for enhanced measurement" in<br />

CELL_INFO_LIST.<br />

If the IE "Frequency index list for enhanced measurement" is received by the UE and the UE does not support enhanced<br />

inter-frequency measuremen<strong>ts</strong> without compressed mode:<br />

1> The UE behaviour is unspecified.<br />

If any two or more of the IE "Adjacent frequency index", the IE "Inter-band frequency index" or the IE "Frequency<br />

index list for enhanced measurement" are received in the same message:<br />

1> The UE behaviour is unspecified.<br />

8.6.7.28 E-UTRA measurement for CELL_FACH<br />

The IE "E-UTRA measurement for CELL_FACH" is used to control the E-UTRA measuremen<strong>ts</strong> and reporting in<br />

CELL_FACH state.<br />

For FDD if the IE "E-UTRA measurement for CELL_FACH" is received by the UE in a MEASUREMENT<br />

CONTROL message, UE shall:<br />

1> if the IE "Measurement command" has the value "setup":<br />

2> if any of the IE’s "Report criteria", "Measurement quantity", "E-UTRA frequencies for measurement" or<br />

"Reporting Threshold" is not received, the UE shall:<br />

3> clear all stored measurement control information related associated to this measurement identity in<br />

variable MEASUREMENT_IDENTITY;<br />

3> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />