3GPP TS 25.331 version 12.3.0 Release 12<br />

1771<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

UE-InternalMeasurement ::= SEQUENCE {<br />

ue-InternalMeasQuantity UE-InternalMeasQuantity OPTIONAL,<br />

ue-InternalReportingQuantity UE-InternalReportingQuantity OPTIONAL,<br />

reportCriteria<br />

UE-InternalReportCriteria<br />

}<br />

UE-InternalMeasurement-r4 ::= SEQUENCE {<br />

ue-InternalMeasQuantity UE-InternalMeasQuantity OPTIONAL,<br />

ue-InternalReportingQuantity UE-InternalReportingQuantity-r4 OPTIONAL,<br />

reportCriteria<br />

UE-InternalReportCriteria<br />

}<br />

UE-InternalMeasurementSysInfo ::= SEQUENCE {<br />

ue-InternalMeasurementID MeasurementIdentity DEFAULT 5,<br />

ue-InternalMeasQuantity<br />

UE-InternalMeasQuantity<br />

}<br />

UE-InternalReportCriteria ::= CHOICE {<br />

ue-InternalReportingCriteria UE-InternalReportingCriteria,<br />

periodicalReportingCriteria<br />

PeriodicalReportingCriteria,<br />

noReporting<br />

NULL<br />

}<br />

UE-InternalReportingCriteria ::= SEQUENCE {<br />

ue-InternalEventParamList UE-InternalEventParamList OPTIONAL<br />

}<br />

UE-InternalReportingQuantity ::= SEQUENCE {<br />

ue-TransmittedPower<br />

BOOLEAN,<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

ue-RX-TX-TimeDifference<br />

BOOLEAN<br />

},<br />

tdd SEQUENCE {<br />

appliedTA<br />

BOOLEAN<br />

}<br />

}<br />

}<br />

UE-InternalReportingQuantity-r4 ::= SEQUENCE {<br />

ue-TransmittedPower<br />

BOOLEAN,<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

ue-RX-TX-TimeDifference<br />

BOOLEAN<br />

},<br />

tdd SEQUENCE {<br />

tddOption CHOICE {<br />

-- appliedTA applies to both 3.84 Mcps TDD and to 7.68 Mcps TDD.<br />

-- Therefore, no additional choice of TDD mode is necessary<br />

tdd384 SEQUENCE {<br />

appliedTA<br />

BOOLEAN<br />

},<br />

tdd128 SEQUENCE {<br />

t-ADVinfo<br />

BOOLEAN<br />

}<br />

}<br />

}<br />

}<br />

}<br />

-- TABULAR: UE-MeasurementQuantity, for 3.84 Mcps TDD only the first two values<br />

-- ue-TransmittedPower and utra-Carrier-RSSI are used.<br />

-- For 1.28 Mcps TDD ue-RX-TX-TimeDifference corresponds to T-ADV in the tabular<br />

UE-MeasurementQuantity ::= ENUMERATED {<br />

ue-TransmittedPower,<br />

utra-Carrier-RSSI,<br />

ue-RX-TX-TimeDifference }<br />

UE-PowerHeadroomThreshold ::= INTEGER (-50..33)<br />

UE-RX-TX-ReportEntry ::= SEQUENCE {<br />

primaryCPICH-Info<br />

PrimaryCPICH-Info,<br />

ue-RX-TX-TimeDifferenceType1 UE-RX-TX-TimeDifferenceType1<br />

}<br />

UE-RX-TX-ReportEntryList ::=<br />

SEQUENCE (SIZE (1..maxRL)) OF<br />

UE-RX-TX-ReportEntry<br />

ETSI