28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3GPP TS 25.331 version 12.3.0 Release 12<br />

1645<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

e-dch-tti-32,<br />

e-dch-tti-64,<br />

e-dch-tti-128,<br />

e-dch-tti-256,<br />

e-dch-tti-512,<br />

e-dch-tti-Infinity,<br />

spare5,<br />

spare4,<br />

spare3,<br />

spare2,<br />

spare1 }<br />

MaxAllowedUL-TX-Power ::= INTEGER (-50..33)<br />

MaxAvailablePCPCH-Number ::= INTEGER (1..64)<br />

MaxPowerIncrease-r4 ::= INTEGER (0..3)<br />

MaxTFCI-Field2Value ::= INTEGER (1..1023)<br />

Measurement-Feedback-Info ::= SEQUENCE {<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

measurementPowerOffset<br />

MeasurementPowerOffset,<br />

feedback-cycle<br />

Feedback-cycle,<br />

cqi-RepetitionFactor<br />

CQI-RepetitionFactor,<br />

}<br />

}<br />

},<br />

tdd<br />

deltaCQI<br />

NULL<br />

DeltaCQI<br />

Measurement-Feedback-Info-r7 ::= SEQUENCE {<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

measurementPowerOffset<br />

MeasurementPowerOffset,<br />

feedback-cycle<br />

Feedback-cycle-r7,<br />

cqi-RepetitionFactor<br />

CQI-RepetitionFactor,<br />

}<br />

}<br />

},<br />

tdd<br />

deltaCQI<br />

NULL<br />

DeltaCQI<br />

Measurement-Feedback-Info-r11 ::= SEQUENCE {<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

measurementPowerOffset<br />

MeasurementPowerOffset,<br />

feedback-cycle<br />

Feedback-cycle-r7,<br />

}<br />

}<br />

},<br />

tdd<br />

cqi-RepetitionFactor<br />

CQI-RepetitionFactor,<br />

cqi-RepetitionFactor-Assisting CQI-RepetitionFactor OPTIONAL,<br />

deltaCQI<br />

DeltaCQI-r11<br />

NULL<br />

Measurement-Feedback-Info-r12 ::= SEQUENCE {<br />

modeSpecificInfo CHOICE {<br />

fdd SEQUENCE {<br />

measurementPowerOffset<br />

MeasurementPowerOffset,<br />

feedback-cycle<br />

Feedback-cycle-r7,<br />

hs-DPCCHOverheadReduction HS-DPCCHOverheadReduction OPTIONAL,<br />

}<br />

}<br />

},<br />

tdd<br />

cqi-RepetitionFactor<br />

CQI-RepetitionFactor,<br />

cqi-RepetitionFactor-Assisting CQI-RepetitionFactor OPTIONAL,<br />

deltaCQI<br />

DeltaCQI-r11<br />

NULL<br />

HS-DPCCHOverheadReduction ::= SEQUENCE {<br />

hs-dpcch-ReductionType ENUMERATED { reductionType1, reductionType2} OPTIONAL,<br />

feedback-cycle2<br />

Feedback-cycle2,<br />

cqi-CycleSwitchTimer<br />

CQI-CycleSwitchTimer<br />

}<br />

Measurement-Feedback-Info-ConcurrentTTI ::= SEQUENCE {<br />

feedback-cycle Feedback-cycle-r7 OPTIONAL,<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!