28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

3GPP TS 25.331 version 12.3.0 Release 12<br />

575<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />

In case of 1a or 1e event-triggered reporting:<br />

1> if the IE "Intra-frequency measurement quantity" is set to "pathloss", the UE shall:<br />

2> if detected set cells are indicated as possibly triggering the event within the IEs "Triggering condition 2":<br />

3> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />

In case of 1a or 1e event-triggered reporting on the secondary uplink frequency:<br />

1> if the IE "Intra-frequency measurement quantity" is set to "pathloss", the UE shall:<br />

2> if detected set cells are indicated as possibly triggering the event within the IEs "Triggering condition 2" in<br />

the IE "Intra-frequency measurement reporting criteria on secondary UL frequency":<br />

3> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />

8.6.7.17 Quality measurement<br />

If IE "Quality measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE<br />

"measurement command" has the value "setup", but IE "Quality reporting quantity" is not received, the UE shall:<br />

1> clear all stored measurement control information related associated to this measurement identity in variable<br />

MEASUREMENT_IDENTITY;<br />

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />

If Transport Channel BLER reporting is requested in IE "Quality Reporting Quantity", but no transport channels are<br />

explicitly referenced with transport channel identities, the UE shall<br />

1> report BLER for all downlink transport channels, for which Transport Channel BLER is defined and can be<br />

requested [7, 8].<br />

If a transport channel, for which Transport Channel BLER is not defined and can not be requested [7, 8], is referenced<br />

with a transport channel identity in IE "Quality Reporting Quantity" and/or IE "Quality Measurement Reporting<br />

Criteria":<br />

1> the UE behaviour is not specified.<br />

8.6.7.18 UE internal measurement<br />

If IE "UE internal measurement" is received by the UE in a MEASUREMENT CONTROL message, where IE<br />

"measurement command" has the value "setup", but IE "UE internal measurement quantity", IE "UE internal reporting<br />

quantity" or "parameters sent for each UE internal measurement event" (given "CHOICE report criteria" is set to "UE<br />

internal measurement reporting criteria") is not received, the UE shall:<br />

1> clear all stored measurement control information related associated to this measurement identity in variable<br />

MEASUREMENT_IDENTITY;<br />

1> set the variable CONFIGURATION_INCOMPLETE to TRUE.<br />

8.6.7.18a<br />

Void<br />

8.6.7.19 UE positioning<br />

8.6.7.19.0 UE positioning reporting criteria<br />

If IE "UE positioning reporting criteria" is included, the UE shall:<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!