3GPP TS 25.331 version 12.3.0 Release 12<br />

333<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

1> else:<br />

2> stop monitoring the list of E-UTRA frequencies assigned in the IE "E-UTRA frequency and priority info list"<br />

in System Information Block type 19;<br />

1> for FDD, if variable HS_DSCH_RECEPTION_CELL_FACH_STATE is set to TRUE and the variable<br />

HS_DSCH_DRX_CELL_FACH_STATUS is set to TRUE:<br />

2> perform measuremen<strong>ts</strong> on other systems according to the requiremen<strong>ts</strong> in [19], during the frame(s) with the<br />

SFN value not fulfiling the inequality specified in subclause 8.5.49.<br />

1> for FDD, if variable HS_DSCH_RECEPTION_CELL_FACH_STATE is set to TRUE and the variable<br />

HS_DSCH_DRX_CELL_FACH_2CYCLE_STATUS is set to TRUE:<br />

2> perform measuremen<strong>ts</strong> on other systems according to the requiremen<strong>ts</strong> in [19], during the frame(s) with the<br />

SFN value not fulfiling the inequality specified in subclause 8.5.49b.<br />

1> otherwise:<br />

2> perform measuremen<strong>ts</strong> on other systems, according to the IE "FACH measurement occasion info", as<br />

specified in subclause 8.5.11.<br />

1> for TDD:<br />

2> perform measuremen<strong>ts</strong> on other frequencies according to the IE "FACH measurement occasion info".<br />

8.4.1.9.4 Traffic volume measurement<br />

Upon transition from idle mode to CELL_FACH state, the UE shall:<br />

1> store the measurement control information from the IE "Traffic volume measurement system information"<br />

received in System Information Block type 12 (or System Information Block type 11, according to subclause<br />

8.1.1.6.11) in the variable MEASUREMENT_IDENTITY;<br />

1> begin traffic volume measurement reporting according to the assigned information.<br />

8.4.1.9.5 UE positioning measurement<br />

Upon transition from idle mode to CELL_FACH state, the UE may:<br />

1> begin or continue monitoring assistance data received in System Information Block type 15 or System<br />

Information Block type 15.1 or System Information Block type 15.2 or System Information Block type 15.3 or<br />

System Information Block type 15.4 or System Information Block type 15.5 or System Information Block type<br />

15bis or System Information Block type 15.1bis or System Information Block type 15.1ter or System<br />

Information Block type 15.2bis or System Information Block type 15.2ter or System Information Block type<br />

15.3bis or System Information Block type 15.6 or System Information Block type 15.7 or System Information<br />

Block type 15.8 according to subclause 8.1.1.6.15;<br />

1> if the IE "UE positioning OTDOA neighbour cell list for UE assisted" stored in the variable<br />

UE_POSITIONING_OTDOA_DATA_UE_ASSISTED; or<br />

1> if the IE "UE positioning OTDOA neighbour cell list for UE based" stored in the variable<br />

UE_POSITIONING_OTDOA_DATA_UE_BASED contains neighbour cells on other frequencies than the<br />

current frequency:<br />

2> perform measuremen<strong>ts</strong> on other frequencies according to the IE "FACH measurement occasion info".<br />

8.4.1.9a<br />

Measuremen<strong>ts</strong> after transition from connected mode to idle mode<br />

Upon transition from connected mode to idle mode the UE shall:<br />

1> stop measurement reporting for all measuremen<strong>ts</strong> stored in the variable MEASUREMENT_IDENTITY;<br />

1> clear the variable MEASUREMENT_IDENTITY;<br />