3GPP TS 25.331 version 12.3.0 Release 12<br />

1059<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information Element/Group Need Multi Type and Semantics Version<br />

name<br />

reference description<br />

Dynamic SF usage MP Boolean REL-7<br />

First Individual timeslot info MP Individual Individual timeslot REL-7<br />

timeslot info<br />

10.3.6.37<br />

info for the first<br />

timeslot used by<br />

the physical layer.<br />

First timeslot Code List MP 1..2 Code list used in REL-7<br />

the timeslot. given<br />

in First individual<br />

timeslot info.<br />

>Channelisation Code MP Enumerated(<br />

REL-7<br />

(1/1),)(2/1),(<br />

2/2),(4/1)..(4/<br />

4),(8/1)..(8/8.<br />

16/1) ..<br />

(16/16).(32/1<br />

)..(32/32))<br />

CHOICE more timeslo<strong>ts</strong> MP REL-7<br />

>No more timeslo<strong>ts</strong> (no data) REL-7<br />

>Consecutive timeslo<strong>ts</strong><br />

>>Number of additional<br />

timeslo<strong>ts</strong><br />

MP<br />

>Timeslot list<br />

>>Additional timeslot list MP 1 to<br />

<br />

Integer(1..m<br />

axTS-1)<br />

The timeslo<strong>ts</strong><br />

used by the<br />

physical layer<br />

shall be timeslo<strong>ts</strong>:<br />

N mod maxTS<br />

(N+1) mod maxTS<br />

...<br />

(N+k) mod maxTS<br />

in that order,<br />

where N is the<br />

timeslot number in<br />

the First individual<br />

timeslot info and k<br />

the Number of<br />

additional<br />

timeslo<strong>ts</strong>.<br />

The additional<br />

timeslo<strong>ts</strong> shall use<br />

the same<br />

parameters (e.g.<br />

channelisation<br />

codes, midamble<br />

shif<strong>ts</strong> etc.) as the<br />

first timeslot.<br />

The first instance<br />

of this parameter<br />

corresponds to the<br />

timeslot that shall<br />

be used second<br />

by the physical<br />

layer, the second<br />

to the timeslot that<br />

shall be used third<br />

and so on.<br />

REL-7<br />

REL-7<br />

REL-7<br />

REL-7<br />

>>>CHOICE parameters MP REL-7<br />

>>>>Same as last<br />

REL-7<br />

>>>>>Timeslot number MP Timeslot<br />

Number<br />

10.3.6.84<br />

REL-7<br />

>>>>New parameters<br />

This physical layer<br />

shall use the<br />

same parameters<br />

(e.g.<br />

channelisation<br />

codes, midamble<br />

shif<strong>ts</strong> etc.) for this<br />

timeslot as for the<br />

last one.<br />

REL-7<br />