28.11.2014 Views

ts_125331v120300p

ts_125331v120300p

ts_125331v120300p

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3GPP TS 25.331 version 12.3.0 Release 12<br />

1157<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Information<br />

Element/Group name<br />

>Periodical reporting<br />

information-1b<br />

>Use CIO<br />

Reporting criteria for<br />

secondary UL Frequency<br />

Cells to be excluded in<br />

detected set cells<br />

Need Multi Type and<br />

reference<br />

CV–<br />

Periodical<br />

clause 9<br />

reporting<br />

info-1b<br />

10.3.7.53<br />

aa<br />

CVclause<br />

10<br />

CV-<br />

Clause<br />

11<br />

CV-<br />

Clause<br />

12<br />

1 to <<br />

maxExcl<br />

udedDet<br />

ectedSet<br />

Cells ><br />

Boolean<br />

Intrafrequency<br />

measure<br />

ment<br />

reporting<br />

criteria on<br />

secondar<br />

y UL<br />

frequency<br />

10.3.7.11<br />

9<br />

>Primary CPICH info MP Primary<br />

CPICH<br />

info<br />

10.3.6.60<br />

Semantics description<br />

In case the IE "Intrafrequency<br />

reporting<br />

criteria" is included in<br />

the IE "Inter-frequency<br />

measurement", this IE<br />

is not needed.<br />

TRUE indicates that the<br />

cell individual offset<br />

shall be used for event<br />

evaluation<br />

If present the UE<br />

should exclude<br />

indicated cells in the<br />

event evaluation when<br />

intra-frequency<br />

detected set is enabled.<br />

Version<br />

REL-5<br />

REL-5<br />

REL-9<br />

REL-11<br />

Condition<br />

Clause 0<br />

Clause 1<br />

Clause 2<br />

Clause 3<br />

Clause 4<br />

Clause 5<br />

Clause 6<br />

Clause 7<br />

Clause 8<br />

Clause 9<br />

Clause 10<br />

Clause 11<br />

Clause 12<br />

Explanation<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1b" or "1f", otherwise the IE is not needed.<br />

The IE is optional if the IE "Intra-frequency event identity" is set to "1a" or<br />

"1b", otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1a" or "1b", otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to , "1e", "1f", "1h" or "1i", otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1a", otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1c" or 1j , otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1a" or "1e", otherwise the IE is not needed.<br />

The IE is mandatory present if the IE "Intra-frequency event identity" is set<br />

to "1a", "1c" or 1j, otherwise the IE is not needed.<br />

The IE is optional if the IE "Intra-frequency event identity" is set to "1e",<br />

"1f", "1h" or "1i". Otherwise the IE is not needed.<br />

The IE is optional if the IE "Intra-frequency event identity" is set to "1b",<br />

otherwise the IE is not needed.<br />

The IE is optional if the IE "Intra-frequency event identity" is set to "1d",<br />

otherwise the IE is not needed.<br />

The IE is not needed when sent in SYSTEM INFORMATION or when IE<br />

"Intra-frequency measurement reporting criteria" is included in the IE "Interfrequency<br />

measurement", otherwise the IE is optional.<br />

The IE is optional if the intra-frequency detected set is configured to trigger<br />

the measurement event, otherwise the IE is not needed.<br />

ETSI

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!