3GPP TS 25.331 version 12.3.0 Release 12<br />

2099<br />

ETSI TS 125 331 V12.3.0 (2014-10)<br />

Equation 1:<br />

3> store in the variable BEST_CELL_3D_EVENT the EARFCN and Physical Cell Identity of the E-UTRA<br />

cell that has the best measured quantity among the EARFCNs considered in that inter-RAT measurement;<br />

3> send a measurement report with IE set as below:<br />

4> set in "E-UTRA measurement resul<strong>ts</strong>": "inter-RAT event identity" to "3d", and "E-UTRA Carrier<br />

Frequency" and "Physical Cell Identity" to the EARFCN and the Physical Cell Identity that are stored<br />

in the variable BEST_CELL_3D_EVENT;<br />

4> set the IE "E-UTRA measured resul<strong>ts</strong>" according to subclause 8.6.7.5.<br />

2> if equation 1 below has been fulfilled for a time period indicated by "time to trigger" for a cell on one of the<br />

EARFCNs considered in that inter-RAT measurement and different from the cell stored in<br />

BEST_CELL_3D_EVENT:<br />

M ≥ M + H<br />

New<br />

Best<br />

3> store the EARFCN and Physical Cell Identity of that E-UTRA cell in the variable<br />

BEST_CELL_3D_EVENT;<br />

3> send a measurement report with IEs set as below:<br />

4> set in "E-UTRA event resul<strong>ts</strong>": "inter-RAT event identity" to "3d", and "E-UTRA carrier frequency"<br />

and "Physical Cell Identity" to the EARFCN and the Physical Cell Identity that are now stored in the<br />

variable BEST_CELL_3D_EVENT;<br />

4> set the IE "E-UTRA measured resul<strong>ts</strong>" according to subclause 8.6.7.5.<br />

3d<br />

/2<br />

The variables in the formula are defined as follows:<br />

M New is the measurement quantity for a cell of the other system that is not stored in the variable<br />

BEST_CELL_3D_EVENT.<br />

M Best is the measurement quantity for a cell of the other system that is stored in the variable<br />

BEST_CELL_3D_EVENT.<br />

H 3d is the hysteresis parameter for event 3d.<br />

14.3.2 GSM measuremen<strong>ts</strong> in compressed mode<br />

14.3.2.1 GSM RSSI measuremen<strong>ts</strong><br />

The UE shall perform GSM RSSI measuremen<strong>ts</strong> in the gaps of compressed mode pattern sequence specified for GSM<br />

RSSI measurement purpose.<br />

14.3.2.2 Initial BSIC identification<br />

The UE shall perform Initial BSIC identification in compressed mode pattern sequence specified for Initial BSIC<br />

identification measurement purpose.<br />

The parameter "N identify abort" in the IE "DPCH compressed mode info" indicates the maximum number of patterns<br />

that the UE shall use to attempt to decode the unknown BSIC of the GSM cell in the initial BSIC identification<br />

procedure.<br />

The BSIC identification procedure is defined in detail in [19].<br />

14.3.2.3 BSIC re-confirmation<br />

The UE shall perform BSIC re-confirmation in compressed mode pattern sequence specified for BSIC re-confirmation<br />