BOC Immingham Dissolved Acetylene Project Environmental Statement: Vol. 2 Main Text<br />

Survey Equipment<br />

Figure 11.1 Noise Survey Measurement Positions<br />

11.46 A Norsonic 118 (Serial No. 31609) with a type 1225 microphone (Serial No. 52305) was used to<br />

perform the short-term satellite measurements. A BrÜel & Kjaer 2238 Mediator (Serial No.<br />

2381615) with a type 4188 microphone (Serial No. 2372203) was used to perform the continuous<br />

long-term measurements at Position A.<br />

11.47 Calibration of the sound level meters and microphones used for the measurements are traceable<br />

to UKAS accredited laboratories. The calibration of both sound level meters and microphones was<br />

checked using a 1 kHz tone at 114 dB prior to and following the measurements performed. No<br />

significant drift in calibration was observed.<br />

Short Term Noise Monitoring<br />

11.48 Table 11.5 presents a summary of results with regard to the short-term measured noise levels.<br />

Table 11.5 Results of Short-Term Noise Measurements<br />

Position Date Start Time LAeq,15min LA90,15min LAFmax,15min<br />

1 06/06/2011 13:35 52.0 47.8 71.4<br />

1 06/06/2011 13:50 53.0 49.8 72.3<br />

1 06/06/2011 21:15 51.0 45.9 73.9<br />

1 06/06/2011 23:40 49.5 43.9 61.3<br />

1 07/06/2011 10:50 55.4 52.1 73.5<br />

5100935.404 Environmental Statement August 2011 195