05.02.2013 Views

View - North East Lincolnshire Council

View - North East Lincolnshire Council

View - North East Lincolnshire Council

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

BOC Immingham Dissolved Acetylene Project Environmental Statement: Vol. 2 Main Text<br />

Storage<br />

3.148 There will be three Lime Storage Tanks (see Figure 3.3), these will be elevated (13.2 m high) to<br />

allow tankers to pass beneath the containers for loading from the top. The arrangement of the<br />

containers will allow two tankers to be filled side by side. The Rotary Drum Filters are also located<br />

on the elevated platform, adjacent to the Lime Tanks.<br />

3.149 Two deluge water tanks and the Deluge Lagoon are located near to the Amenities Building.<br />

3.150 The N2 VIE Tank (which is 4 m high) is located to the south east of the Cylinder Examination Shop<br />

and to the north east of the Empty Cylinder Storage Area.<br />

3.151 The Acid and Lye Storage Area is located to the north east of the Generator Building, with a<br />

footprint of 12 m 2 .<br />

3.152 The Waste Liquor Storage Tanks and the Lime Sump are on the north western gable of the<br />

Generator Building.<br />

3.153 The Rainwater Harvesting Tank and Cooling Water Tower are also adjacent to the south eastern<br />

gable of the Generator Building.<br />

3.154 The Acetone Tank is located between the Lime Storage Area and Surplus Cylinder Store.<br />

3.155 The south east corner of the main process the main process area will provide the following<br />

storage areas:<br />

� Empty Cylinder Storage (footprint approximately 168 m 2 );<br />

� Cylinder Examination Shop Storage (footprint approximately 131 m 2 ); and<br />

� Empty Bundle Storage (footprint approximately 128 m 2 ).<br />

3.156 The west side of the main process area will provide the following storage areas:<br />

� Full Bundle Storage (footprint approximately 128 m 2 );<br />

� Full Cylinder Storage (footprint approximately 128 m 2 ); and<br />

� Surplus Cylinder Storage (footprint approximately 128 m 2 ).<br />

3.157 Cylinder and bundle storage areas are open areas (i.e. no roof or exterior walls).<br />

Vehicle Related Areas<br />

3.158 There will be a number of vehicle related areas around the edge of the main process area. All of<br />

these areas will be within the one way loop road.<br />

3.159 An area for container loading will be located on the north western side of the main process area,<br />

close to the Lime Storage Tanks. In the south east corner there will be an area for vehicle<br />

unloading. A trailer assembly area will be located at the centre of the south eastern boundary.<br />

Two vehicle parking areas will be located on the south western boundary.<br />

Pipe Racking<br />

3.160 Pipe racking will provide a link from the Lime Storage tanks to the Generator Building. An<br />

additional set of racking links the Generator Building to the Cylinder and Bundle Filling Building<br />

and the Cylinder Examination Shop.<br />

5100935.404 Environmental Statement August 2011 42