24.12.2013 Views

View/Open - ARAN - National University of Ireland, Galway

View/Open - ARAN - National University of Ireland, Galway

View/Open - ARAN - National University of Ireland, Galway

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Chapter 2<br />

range <strong>of</strong> 0.05-0.12 on granite, 0.05-0.22 on marble, 0.05-0.21 on stainless<br />

steel, 0.10-0.41 on white silestone and between 0.01-0.19 on beige<br />

silestone [98]. The SD values were based on four repeated experiments<br />

with three replicates used on each occasion (n=12). The low SD values<br />

reported in the text may indicate the level <strong>of</strong> stability when using a closed<br />

batch-flow model where each test material is examined separately (no<br />

mixing <strong>of</strong> nutrients or planktonic cells in contact with multiple surfaces)<br />

[98]. Moreover, the limited number <strong>of</strong> variables such as flow <strong>of</strong> nutrients,<br />

shear stress and position within a multi-coupon reactor system (robustness<br />

<strong>of</strong> method) may have contributed to the low SD values gained in the<br />

research.<br />

Stocki et al. examined bi<strong>of</strong>ilm formation <strong>of</strong> S. Enteritidis and S.<br />

Typhimurium on plastic materials (vinyl, nylon, hemp plastic, farmers belt,<br />

plastic) commonly used for manufacturing conveyor belts in egg processing<br />

facilities [67]. Stocki and colleagues calculated the mean log 10 density <strong>of</strong><br />

cells <strong>of</strong> the five belt types by enumerating the log 10 CFU/cm -2 <strong>of</strong> cells<br />

recovered from a set <strong>of</strong> 5 belt pieces stored in 3 petri dishes (n=15 for each<br />

belt type).The surfaces were incubated at 28°C for a total <strong>of</strong> 14 days to<br />

form a bi<strong>of</strong>ilm, consisting <strong>of</strong> 7 days incubation pre- and 7 days posttreatment<br />

with disinfectant. Despite the repeated measures and extensive<br />

use <strong>of</strong> replicates, Stocki et al. found large variation in measurement which<br />

was still evident post log transformation <strong>of</strong> the data. The large variation<br />

between repeated measurements was highlighted through the use <strong>of</strong><br />

interquartile range for non parametric data which ranged between 0-2.5<br />

log 10 CFU/1cm 2 depending on material and strain tested [67].<br />

Page<br />

48

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!